Log:
Évaluations - , GPA: ( )

Instructions Crown, Modèle S9360A

Fabricant : Crown
Taille : 1.22 mb
Nom Fichier : ad76b75a-c0f3-4a06-b130-ecea5f97dab3.pdf

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


5. Hot Surface Ignition Wiring (S937X). Common Connectors Table 3. Connectors Common to Both Spark-to-Pilot and Hot Surface Ignition Options. Connection/Color Pin Mating Plug Description Flame Sense 1 of 1 3/16 in. female quick- connect Connection to Flame Rod Sensor 1/White 1 of 3 Molex® 43061-0003 NTC 1-1 2 of 3 Sensor Common 3 of 3 NTC 1-2 Sensor 2a/White 1 of 2 Molex® 43061-0002 NTC Temperature Sensor 2 of 2 69-2076—01 8 S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS Connection/Color Pin Mating Plug Description EnviraCOM/Black 1 of 3 Stripped Bare Wire ECOM Data “1” 2 of 3 ECOM R “2” 3 of 3 ECOM C “3” EnviraCOM Diag/ White 1 of 3 “Pen” Diagnostic Tool with 0.1 in. spacing ECOM Data “1” 2 of 3 ECOM R “2” 3 of 3 ECOM C “3” Transformer Primary/ White 1 of 3 Molex® 50-81-1030 L1 2 of 3 Earth Ground 3 of 3 Neutral Transformer Secondary/White 1 of 2 Molex® 50-81-1020 24 Vac Input 2 of 2 Earth Ground “Control”/White 1 of 9 Molex® 50-81-1090 Pressure Switcha 2 of 9 Pilot Valvea 3 of 9 Pressure Switcha 4 of 9 AC N.C. Switch 5 of 9 Main Valve 6 of 9 AC N.C. Switch 7 of 9 N.C. 8 of 9 MV/PV (Valve Common) 9 of 9 N.C. a Indicates optional connection based on configuration. HSI Model Specific Connectors In addition to the common connectors listed above, Table 4 identifies connectors available on the HSI model board assemblies. Table 4. HSI Model Specific Connectors. Connection Pin Mating Plug Description On/Off Circulatora/White 1 of 4 Molex® 50-84-1061 L1 Relay Out 2 of 4 Earth Ground 3 of 4 Neutral 4 of 4 Neutral Line Voltage Input/Red 1 of 3 Molex® 50-84-1031 L1 2 of 3 Earth Ground 3 of 3 Neutral Induced Draft Blower (Combustion Air)/Red 1 of 4 Molex® 50-84-1041 L1 Relay Out 2 of 4 Earth Ground 3 of 4 Neutral 4 of 4 Neutral HSI/Red 1 of 2 Molex® 50-84-1021 L1 Relay Out 2 of 2 Flame Sense/(N) Relay Out a Indicates optional connection based on configuration. 9 69-2076—01 S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS Connection Pin Mating Plug Description Line Voltage Input/White 1 of 4 Molex® 50-81-1040 L1 2 of 4 Earth Ground 3 of 4 Earth Ground 4 of 4 Neutral Induced Draft Blower (Combustion Aira)/White 1 of 6 Molex® 39-01-2060 Earth Ground 2 of 6 N/C 3 of 6 Neutral 4 of 6 N/C 5 of 6 L1 Relay Out 6 of 6 N/C Vent Dampera/White 1 of 6 24 Vac 2 of 6 Damper E.S. Feedback 3 of 6 24V Common if damper connected 4 of 6 24V Common 5 of 6 Damper Activation 6 of 6 N/C Spark Rod 1 of 1 1/4 in. female quick- connect Connection to Spark Rod On/Off Circulatora/Red 1 of 2 Molex® 50-84-1021 L1 Relay Out 2 of 2 Neutral a Indicates optional connections based on configuration. Table 6. Pin Configuration. Wire Harness Housing Pin Configuration Pin/Socket Molex® Number Line In pin 02-08-2004 Transformer Primary socket 02-08-1002 Transformer Secondary socket 02-08-1002 Circulator pin 02-08-2004 Damper pin 03-06-2103 Inducer sock...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - S9360A (1.22 mb)
Chauffe-eau - S9360A (1.22 mb)
Chauffe-eau - S9361A (1.22 mb)
Chauffe-eau - S9370A (1.22 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories