Log:
Évaluations - 4, GPA: 4.3 ( )

Instructions Enerco, Modèle TSBF10NG

Fabricant : Enerco
Taille : 1000.98 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Operate buner until air is removed from line have gas line checked by local gas company. 3. Observe minimum installation clearances(see Figure 4 page6) 4. Clean burner orifice (see Cleaning and Maintenance on page 13), or replace burner orifice. White powder residue forming within burner box or on adjacent walls or furniture 1. When heated, vapors from furniture polis, wax, carpe cleaners, etc., turn into white powder residue 1. Turn heater off when using furniture poils,wax, carpet cleaner or similar products. TROUBLESHOOTING WARNING: If you smell gas: • Shut off gas supply • Do not try to light any appliance • Do not touch any electrical switch; do not use any phone in your building • Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. 15 OBSERVED SYMPTOM POSSIBLE CAUSE REMEDY 1. Heater burning vapors from paint, hair spray, glues, etc. See IMPORTANT statement above 2. Gas leak. See WARNING statement at top of page. 1. Not enough fresh air is available 2. Low line pressure 3. ODS/pilot is partially clogged 1. Gas leak. See WARNING statement at top of page 2. Control valve is defective 1. Foreign matter between control valve and burner 2. Gas leak. See WARNING statement at top of page 1. Metal expanding while heating or contracting while cooling 1. Not enough combustion/venitlation air 1. Ventilate room. Stop using odor-causing products while heater is running. 2. Locate and correct all leaks (see Checking Gas Connections, page 8) 1. Open window and/or door for ventilation 2. Contact local gas company 3. Clean ODS/pilot (see Cleaning and Maintenance, page 13) 1. Locate and correct all leaks (see Checking Gas Connections, page 8) 2. Replace control valve 1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections, page 8) 1. This is common with most heaters. If noise is excessive, contact qualified service person 1. Refer to Fresh Air of Combustion and Ventilation page 3 through 5 Heater produces unwanted odors. Heater shuts off in use (ODS operates) Gas odor even when control knob is in OFF position Gas odor during combustion Heater produces a cliking/ ticking noise just after butner is lit or shut off Moisture/condensation noticed on windows Installation instructions and Owner’s Manual SPECIFICATIONS IR10NG IR20NGT IR30NGT BTU (Available) 10,000 20,000 30,000 Type of Gas Natural Gas Only Natural Gas Only Natural Gas Only Ignition Piezo Battery ignitor (1-AA) Battery ignitor (1-AA) Pressure Regulator Setting 4.5 Inches of Water 4.5 Inches of Water 6.0 Inches of Water Inlet Gas Pressure (Maximum) 14 Inched of Water 14 Inched of Water 14 Inched of Water Inlet Gas Pressure (Minimum) 9 Inches of Water 9 Inches of Water 9 Inches of Water Electrical Rating — 120V, 60Hz, 1 120V, 60Hz, 1 Burners / Orifice nozzles 2 3 4 Thermostatic Control No Yes Yes Clearances: inches (mm) Top 36 (915) 36 (915) 36 (915) Sides 6 (152) 10.5 (267) 10.5 (267) Floor (min. to top of carpet) 2 (51) 2 (51) 2 (51) Fabric / flammable objects 36 (915) 36 (915) 36 (915) BTU (Available) BF10NG BF20NGT BF30NGT 10,000 20,000 30,000 Type of Gas Natural Gas Only Natural Gas Only Natural Gas Only Ignition Piezo Battery ignitor (1-AA) Battery ignitor (1-AA) Pressure Regulator Setting 4.5 Inches of Water 4.5 Inches of Water 4.5 Inches of Water Inlet Gas Pressure (Maximum) 14 Inched of Water 14 Inched of Water 14 Inched of Water Inlet Gas Pressure (Minimum) 9 Inches of Water 9 Inches of Water 9 Inches of Water Electrical Rating — 120V, 60Hz, 1 120V, 60Hz, 1 Burners / Orifice nozzles 1 1 1 Thermostatic Control No Yes Yes Clearances: inches (mm) Top 36 (915) 36 (915) 36 (915) Sides 6 (152) 10.5 (267) 10.5 (267) Floor (min. to top of carpet) 2 (51) 2 (51) 2 (51) Fabric / flammable objects 36 (915) 36 (915) 36 (915) 16 Installation instructions and Owner’s Manual 70574 REV. C 8/05 REPLACEMENT PARTS Note: use only original replacement parts. This will protect you warranty coverage for parts replaced under warranty. REPLACEMENT PARTS Note: use only original replacement parts. This will protect you warranty coverage for parts replaced under warranty. Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call the number on back of manual. When contacting your dealer have ready: • Your name • Your address • Model and serial numbers of your heater • How heater was malfunctioning • Type of gas used (Natural Gas) • Purchase date Usually, we will ask you to return the defective part to the factory. PARTS NOT UNDER WARRANTY Contact authorized dealer of this product. If they can’t su...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - MHBF20/NGT (1000.98 kb)
Chauffe-eau - MHBF10NG (1000.98 kb)
Chauffe-eau - MHBF30NGT (1000.98 kb)
Chauffe-eau - MHIR10NG (1000.98 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories