Log:
Évaluations - 5, GPA: 4.4 ( )

Instructions Empire Comfort Systems, Modèle SR-30-3

Fabricant : Empire Comfort Systems
Taille : 2.81 mb
Nom Fichier :
Langue d'enseignement: enes
Aller à la télécharger



Facilité d'utilisation


If the manual gas control knob is in mid-position, between heat settings, incomplete combustion will take place, causing odor, and may produce gas leakage or carbon monoxide. 10. Turn on all electric power to appliance (if applicable). TO TURN OFF GAS TO APPLIANCE 1. Turn off all electric power to appliance if service is to be performed (if applicable). 2. Push in manual gas control knob slightly and turn clockwise to "OFF". Do not force. PILOT FLAME CHARACTERISTICS The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 17 Oxygen Depletion Sensor Pilot (Figure 16) When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows: 1. Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open end wrench. 2. Blow air pressure through the holes indicated by the arrows. This will blow our foreign materials such as dust, lint and spider webs. Tighten nut B also by grasping nut A. Figure 18 Warning: Never use needles, wires, or similar cylindrical objects to clean the pilot to avoid damaging the calibrated ruby that controls the gas flow. MAIN BURNER OPERATION The main burner operation is MANUAL. The owner must manually place the main burner in operation. The owner will either select one, three or five plaques to be in operation. Once the owner has turned the main burner ON, it will continue to operate until the owner manually turns the main burner OFF. Description of Manual Gas Control Knob: OFF position. PILOT position. SR-6 Position 1 Will have one plaque in operation, the input will be 6,000 BTUH (1.8KW/H). SR-10 Position 1 Will have one plaque in operation, the input will be 10,000 BTUH(2.9KW/H). SR-18 Position 1 Will have one plaque in operation, the input will be 6,700 BTUH (2KW/H). Position 2 Will have two plaques in operation, the input will be 12,000 BTUH (3.5KW/H). Position 3 Will have three plaques in operation, the input will be 18,000 BTUH (5.3KW/H). SR-30 Position 1 Will have one plaque in operation, the input will be 8,000 BTUH (2.3KW/H) for Natural gas and 7,000 Btuh (2.1KW/H) for Propane/LP gas. Position 2 Will have three plaques in operation, the input will be 18,000 BTUH (5.3KW/H). Position 3 Will have five plaques in operation, the input will be 30,000 BTUH (8.8KW/H). PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. SR-6 Index Number Part Number Description 1 13344 CASING SIDE ASSEMBLY – LEFT 2 R-2313 PIEZO IGNITOR 3 R-2328 CONTROL KNOB 4 SR-036 CONTROL ROD 5 SR-126 CASING BACK 6 SR-008 CASING SIDE ASSEMBLY – RIGHT 7 SR-153 ORIFICE SHIELD 8 SR-032 PILOT BRACKET (NAT) 8 SR-250 PILOT BRACKET (LPG) 9 R-6308 PILOT ASSEMBLY (LPG ONLY) (INCLUDES ITEM 10 & 11) 9 R-6307 PILOT ASSEMBLY (NAT ONLY) (INCLUDES ITEM 10 & 11) 10 R-6309 SPARK IGNITOR 11 R-6310 PILOT THERMOCOUPLE 12 SR-143 TUBING – GAS VALVE TO PILOT 13 SR-112 VALVE BRACKET 14 R-2277 GAS VALVE – COPRECI 15 SR-139 TUBING – GAS VALVE TO BURNER 16 SR-221 TUBING – INLET REGULATOR TO GAS VALVE 17 R-5097 INLET REGULATOR – NAT 17 R-5098 INLET REGULATOR – LPG 18 10753 INLET REGULATOR BRACKET 19 R-2314 ORIFICE HOLDER 20 R-2319 MAIN BURNER ORIFICE – NAT 20 R-2320 MAIN BURNER ORIFICE – LPG 21 R-2332 BURNER 22 R-2305 CHROME GRILL 23 SR-134 CASING LOUVER (2 REQUIRED) 24 SR-129 REFLECTOR ASSEMBLY 25 SR-135 HEAT SHIELD 26 SR-154 OPTIONAL SRS-10 FLOOR STAND KIT NS R-2390 IGNITOR WIRE NS SR-216 HARDWARE PACKAGE SR-10 Index Number Part Number Description 1 13345 CASING SIDE ASSEMBLY – LEFT 2 R-2313 PIEZO IGNITOR 3 R-2328 CONTROL KNOB 4 SR-036 CONTROL ROD 5 SR-177 CASING BACK 6 SR-008 CASING SIDE ASSEMBLY – RIGHT 7 R-153 ORIFICE SHIELD 8 SR-179 PILOT BRACKET (NAT) 8 SR-032 PILOT BRACKET (LPG) 9 R-6308 PILOT ASSEMBLY (LPG ONLY) (INCLUDES ITEMS 10 & 11) 9 R-6307 PILOT ASSEMBLY (NAT ONLY) (INCLUDES ITEMS 10 & 11) 10 R-6309 SPARK IGNITOR 11 R-6310 PILOT THERMOCOUPLE 12 SR-143 TUBING – GAS VALVE TO PILOT 13 SR-112 VALVE BRACKET 14 R-2277 GAS VALVE – COPRECI 15 SR-139 TUBING – GAS VALVE TO BURNER 16 SR-221 TUBING – INLET REGULATOR TO GAS VALVE 17 R-5097 INLET REGULATOR – NAT 17 R-5098 INLET REGULATOR – LPG 18 10753 INLET REGULATOR BRACKET 19 R-2314 ORIFICE HOLDER 20 R-2317 MAIN BURNER ORIFICE – NAT 20 R-2476 MAIN BURNER ORIFICE – LPG 21 R-2331 BURNER 22 R-2305 CHROME GRILL 23 SR-134 CASING LOUVER (2 REQUIRED) 24 R-129 REFLECTOR ASSEMBLY 25 R-135 HEAT SHIELD 26 SR-154 OPTIONAL SRS-10 FLOOR STAND KIT NS R-2390 IGNITOR WIRE NS SR-216 HARDWARE PACKAGE USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to th...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - SR-18-3 (2.81 mb)
Chauffe-eau - SR-10-3 (2.81 mb)
Chauffe-eau - SR-6-3 (2.81 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories