Log:
Évaluations - 2, GPA: 3 ( )

Instructions Bryant, Modèle BW1

Fabricant : Bryant
Taille : 337.13 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


† 7–9 Section Models on BS1, BS2, BW1, and BW2; 6–7 Section Models on BW3. Note: Accessory High Limit Control is a strap-on aquastat used as an auxiliary limit or reverse acting circulator control. —3— CIRCULATOR CURVE WATER FLOW M3/H WATER FLOW GPM TOTAL HEAD METERS TOTAL HEAD FEET 1 40 2 4 6 8 10 12 8 12 16 20 24 2 3 4 5 3 2 1 WATER BOILER CIRCULATOR CURVE ELECTRICAL DATA ALL MODELS Voltage—Hertz—Phase 115 — 60 — 1 Minimum Branch Circuit Wire Size (AWG) 14 Maximum Fuse Size (Amps) 15 Control Circuit Power Available 40va–@ 24v STANDARD BOILER WARRANTIES (Yrs) MODEL BW1 BW2 BW3 BW4 BW5 BW9 BS1 BS2 Circulator Pump 3 3 3 3 3 3 — — Vent Damper 5 5 — — — — 5 5 Heat Exchanger Section Assembly (Non-prorated) 20 20 20 20 20 15 12 12 Oil Burner — — — 3 3 — — — ® CERTIFIED ASME ® ama —4— MODELS BW9 The BW9 is a gas fired direct vent condensing hot water boiler with cast aluminum heat exchanger sections. A revolutionary cast aluminum heat exchanger means better heat transfer and thermal storage than similarly sized cast iron boiler, which results in higher efficiency. The heating system water absorbs large amounts of heat from the cast aluminum heat exchanger, cooling the flue gases and causing condensation. Sealed combustion, premix gas burner, and low flame temperature means drastically reduced CO and NOx emissions, which contribute to a cleaner and healthier environment. The BW9, unlike normal residential atmospheric and induced draft boilers, takes its combustion air directly from the outdoors (sealed combustion) and does not compete with building occupants for fresh air. Sealed combustion (also known as “direct vent”) is the safest and best way to obtain plenty of clean combustion air. The induced draft fan draws in the outside combustion air, then takes the cooler flue gases from the heat exchanger and provides a positive removal of the flue gases from the building through inexpensive and readily available PVC and CPVC pipes. FEATURES RANGE OF CAPACITIES—Three sizes ranging from 50,000 through 100,000 Btuh input. COMPLETELY PACKAGED—Each boiler is completely assembled, including all controls (except room thermostat). All necessary wiring is factory installed. The boiler is ready for gas piping, room thermostat, and electrical power connections as shipped. Circulator is shipped pre-wired with 6 ft bx conduit for easy installation for supply side pumping. VENTING—This boiler is direct vented with PVC and CPVC pipe. See the Installation Instructions for common venting requirements. ALUMINUM SECTIONS—These sections speed heat transfer to the boiler water. With faster thermal response, greater comfort and economy are achieved. PRE-MIX BURNER—Provides quiet operation and improved combustion efficiency. CONTROLS—Integrated Boiler Control provides safe, dependable operation of burners. Factory-installed safety components provide maximum safety against overheating, pressure buildup, and low-water operation. SECTIONS TESTED—Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers. PROPANE CONVERTIBLE—With factory approved conversion kit accessory. WARRANTY—The aluminum sections are covered by a limited 15-year warranty on the entire assembly. Circulator pump is covered by a limited 3-year warranty. All other parts are covered by a 1-year limited warranty. SPECIFICATIONS UNIT SIZE 050 075 100 Sections 1 GAS CONTROLS Gas Valve Honeywell Inlet S...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - BS1 (337.13 kb)
Chauffe-eau - BW2 (337.13 kb)
Chauffe-eau - BW3 (337.13 kb)
Chauffe-eau - BW4B (337.13 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories