3. Remove and replace the anode rod N Fig. 5/2. 4. Refill tank with water before restoring power. Changing the heating element Changing the thermostat Resetting High Limit Switch 1. Turn off power supply and drain the heater (see Draining the Heater). 2. Remove the heating element (see section on Removing the Heating Element). 3. Install new element with gasket, making sure the gasket and element are positioned correctly. Tighten the retaining nuts and make the wire connections. 4. Refill tank with water before restoring power. 1. Turn off power supply. 2. Disconnect the 2 push/pull type wires on thermostat. 3. Loosen the two brass screws at right side of thermostat and pull wires out. 4. Unscrew and remove the two phillips screws holding the thermostat down. 5. Install new thermostat and re-attach wiring and screws. Occasionally, the high temperature limit shut off device may trigger and shut the system down. This occurs when water temperature exceeds 190° F and shuts off power to the heating element. The shut off device may also trigger from a power outage or electrical storm. To reach the thermostat: 1. Pry off the round cover plate (V Fig. 3/1) from its right hand edge (W Fig. 3/1) with a small flat-head screwdriver. 2. Remove the Phillips screw revealed beneath the round cover plate. 3. The cover (C Fig. 3/1) can now be removed by pulling out its left-hand edge. When reassembling, work in the opposite way being careful to insert the tongue of the cover into the slot. 4. Firmly press reset button (B Fig. 4). Reconnect power. 5. IMPORTANT: Check the operation of the thermostat, turn temperature dial from high to low, if the red light does not go off on low setting, turn off power supply and call a service person to replace the thermostat. 6. If the system works, place dial setting to desired setting. Note: a lower setting is more economical and reduces the risk of scalding. Replace cover plate. CAUTION: Call a technician if the high limit needs to be reset frequently. Troubleshooting Water does not get hot Light not on Brown water Odor in water Water is too hot 1. Make sure the power supply is on and working. 2. If light does not come on, check that the reset button is pushed in; follow steps from previous section. 3. If the indicator light works properly but temperature does not get hot a tap, test for a plumbing crossover; shut off cold supply to heater and open hot water tap. There should be no water flowing. Any continued flow indicates a crossover which will effect the temperature and will need to be corrected. 4. Replace heating element (see previous section on changing the heating element). 1. If the light does not come on, but water gets hot, check for faulty bulb. 2. Check reset button; follow steps from previous section. 1. Brown or rusty water indicates a “spent” anode rod. Replace anode rod. 1. Smelly water could be due to an unusual reaction between local water and the heater’s anode rod. Check anode rod (see section on changing the anode rod). 1. Remove cover plate and turn the temperature selector dial (D Fig. 4) counter clockwise to lower temperature. If temperature never lowers then replace thermostat. (see section on changing the thermostat). Water not 1. Adjust the temperature selector dial (D Fig. 4) clockwise to increase temperature. hot enough Leaking 1. Check water fittings and T & P fitting on top of tank. 2. Remove front cover and inspect heating element gasket. DESCRIPTION REF. ARISTON INTERIOR COMPONENTS DIAGRAM GL 2.5Ti, 4Ti, 8Ti GL 2.5Ti A PART CODE DESCRIPTION REF. 1 100XL VALVE (T&P 3/4”) ABCGL 4Ti B 2 570241 ANODE (MAGNESIUM) C GL 8Ti C 2 574305 ANODE (MAGNESIUM) AB 3 994147 GASKET WITH 4 BOLTS ABC 4 994140 LOCK NUT M6 ABC 5 994103 HEATING ELEMENT (1500/120) AB 5 994104 HEATING ELEMENT (1500/120) C 6 PLASTIC COVER RETAINING SCREW 7 NAME BADGE (PLASTIC) 8 COVER 9 SWITCH COVER 10 THERMOSTAT WIRING 11 994062 THERMOSTAT AB 11 994102 THERMOSTAT C 12 CABLE CLAMP 13 SUPPLY CABLE AB 14 570341 HEATER WALL HANGING BRACKET ABC 15 gl6plug 3/4” BRASS PLUG (GL6 ONLY) C ARISTON GLTi • LIMITED 8 YEARS WARRANTY COVERAGE ARISTON, THROUGH ITS U.S. DISTRIBUTOR CONTROLLED ENERGY CORP., (hereinafter CEC) guarantees this water heater to the Owner (hereinafter “Owner”) of the water heater at the original installation location against defects in material and workmanship for the periods specified below. WARRANTY PERIOD 1. The inner Tank - If the inner tank leaks within eight (8) years from the date of original installation of the water heater, because of a defect in material or workmanship, CEC will furnish to such Owner a new heater of the then prevailing comparable model. 2. Any Component Part Other than The Original Inner Tank - If any component part (other than the inner tank) proven to be defective in material or workmanship within one (1) year from the date of original installation of the water heater, CEC will furnish the Owner with a replacement of the defective part(s). 3. Verification of ...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - GL 4 Ti (130.54 kb)
Chauffe-eau - GL 8 Ti (130.54 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories