be due to thermal expansion in a closed water system. Contact the water supplier This water heater incorporates a or your plumbing contractor on how to combustion shut off device that shuts correct this. DO NOT plug the relief the operation of the water heater down valve outlet. if undesirable combustion conditions occur. A water heater’s tank can act as a setling Such as the presence of flammable vapors basin for solids suspended in the water. It is or blockage of the combustion air inlet therefore not uncommon for hard water openings. Please contact a Qualified deposits to accumulate in the bottom of the Service Technician if this occurs. tank. If allowed to accumulate, these solids can cover the gas control (thermostat) sensors, causing the sensors to operate erratically. ! DANGER: Combustible materials, such as clothing, cleaning materials, or flammable liquids, etc., must not be placed against or next to the water heater. Housekeeping Visually inspect pilot burner and relight if necessary. To ensure sufficient ventilation and combustion air supply, proper clearances must be maintained. When installed in a closet, DO NOT block or obstruct any of the combustion air inlet openings located around the perimeter of the water heater. A minimum of 1” is required between these combustion air inlet openings and any obstruction. 19 Care and cleaning of the water heater. Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions Venting System Inspection The water heater’s internal flue must be inspected annually to be certain it is clean by removing the draft hood and flue baffle. When reinstalling the flue baffle make certain it is hung securely by its hanger at the top of the flue way. Reinstall the draft hood. Inspect the gas venting system and the chimney. Make certain the vent connector from the draft hood to the chimney is properly positioned and securely attached. If after inspection of the vent system you found sooting or deterioration call the local gas utility to correct the problem and clean the flue, or replace the flue, flue baffle, and venting system before resuming operation of the water heater. Test for spillage at the draft hood relief opening after 5 minutes of burner operation. Use a flame of a match or candle or smoke. Proper burner and pilot flame pattern Burner Inspection Visually inspect the pilot and main burners annually. Through the sight glass, inspect the pilot burner flame with main burner off and inspect the main burner while firing. If any unusual burner operation is noted, the water heater should be shut off until qualified service assistance can be obtained. ! CAUTION: For your safety, cleaning of the main burner must be performed only by qualified service personnel. The burner chamber is a sealed area. If the burner access door is removed, the burner access door gasket must be replaced. For cleaning, remove the burner from the water heater. A vacuum cleaner can be used on the burner and floor shield inside the water heater. The burner can also be cleaned by scrubbing with mild detergent. NOTICE: Refer to the Hydrogen Gas Caution in the Operating Instructions. Vacation and Extended Shut-Down If the water heater is to remain idle for an After a long shut-down period, the water extended period of time, the power and heater’s operation and controls should be water to the appliance should be turned checked by qualified service personnel. off to conserve energy and prevent a build-Make certain the water heater is up of dangerous hydrogen gas. completely filled again before placing it in operation. The water heater and piping should be drained if they might be subjected to freezing temperatures. NOTICE: Do not remove the anode rod from the water heater’s tank, except for inspection and/or replacement, as operation with the anode rod removed will greatly shorten the life of the glass lined tank and will exclude warranty coverage. 20 Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glass lined tank. The anode rod is slowly consumed, thereby eliminating or minimizing corrosion of the glass lined tank. Water sometimes contains a high sulfate and/or mineral content and together with cathodic protection process can produce a hydrogen sulfide, or rotten egg odor in the heated water. Chlorination of the water supply should minimize the problem. Before you call for service… Troubleshooting Tips Save time and money! Review the charts on the following pages first and you may not need to call for service. This water heater incorporates a combustion shut off device that shuts the operation of the water heater down if undesirable combustion conditions occur. Such as the presence of flammable vapors or blockage of the combustion air inlet openings. Please contact a Qualified Service Technician if this occurs. Moisture from the products . This is normal and will disappear in time. Excessive of...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - AP13204-4 (1.53 mb)
Chauffe-eau - HG Series (1.53 mb)
Chauffe-eau - GP Series (1.53 mb)
Chauffe-eau - GG50T06TVG (1.53 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories