Fabricant : Haier
Taille : 1.75 mb
Nom Fichier :
|
Facilité d'utilisation
Please fasten the drain hose to the drain thread of safety valve by twisting (see to Figure 3). Connect the other end of drain hose to the sewer to avoid polluting the room by splashing. When the power is switched on, and the water heater starts operating, there may be some water discharged from the pressure relief hole of safety valve. It is due to the water expansion under heating, and is normal phenomenon. The pressure relief pipe shall communicate with the air directly.Do not Connect to drain hose Installation The water may drip from the discharge pipe of the pressure relied device and that this pipe must be installed in a continuously downward direction and in a frost-free environment . Check safety valve once a month as follow: move the small handle of safety valve, if there's water flowing out, safety valve is normal; if there's no water flow, please contact local after-sales service station. The pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked. block it. The discharged water can be led to the sewer. Select suitable position on the wall to fix the shower nozzle bearer. Connect the shower nozzle hose to the pipeline. Fasten the mixing valve. Check if there's water leakage at each joint. Be sure to check and confirm that the tank is filled with water, there's no leakage at each joint and the power supply complies with the stipulation before switching on the power. 85 6 Setting Environment Description of the Symbols Do not set it at place where is too cold and may freeze. Do not set at outdoor places. Do not use as floorstanding appliance. Please mount it to firm and reliable wall. Do not install to places without sewer. In case connecting water heater with water drain hose, connect the drain hose to the inlet of the sewer to avoid polluting by splashing. The original pipeline of the water heater is an organic part of "PTO 0". Do not remove it by yourself. Otherwise we will not take responsibility for the injure and loss caused by the safety trouble occurred therefrom. Never do that Be sure to act as per instructions Installation Be sure to have it installed by installation staff of the after service department, or the appointed staff. It adopts wall-mounting installation. Make four holes with diameter of 12mm and depth 65mm with churn drill on the wall as per the installation dimension drawing. Insert the bolts into the holes. Then lift the water heater, set the wall-mounting rack on the bolt. Set the gasket and fasten the nut. Install the accessories including safety valve etc. as indicated in Figure 2. Remember to seal with rubber tape to avoid water leakage. The hot water pipe shall not be too long to reduce the heat losses. Please reserve some space in installation for the future maintenance. To facilitate the installation and dismantling, it is suggested to add G 1/2' flexible nut at the suitable position of the water inlet and outlet pipe separately. Confirm the position needing water supply. Connect the water inlet/outlet pipe and tap water pipe to the position respectively. (Figure 2) for reference in installation only Cold water inlet Mixing valve Hot water outlet valve Cold water outlet valve Shower nozzle Hot water outlet Safety valve Connection and use of safety valve: The safety valve should be connected to the cold water inlet pipe. Please check carefully if the direction is correct after installation. The correct direction of installation is that the arrowhead on the safety valve should point to the water heater. Please connect the drain hose to the safety valve. Connect one end of the hose to the safety valve vent and the other end to the sewage drain. The hose can be cut short or extended as necessary. The hose shall be installed as inclined downward. ...
Ce manuel est également adapté pour les modèles :Chauffe-eau - FCD-JTSA60-III (1.75 mb)
Chauffe-eau - FCD-JTSA50-III (1.75 mb)