Log:
Évaluations - 3, GPA: 3.3 ( )

Instructions Heat & Glo LifeStyle, Modèle SUPREME-XTS

Fabricant : Heat & Glo LifeStyle
Taille : 3.15 mb
Nom Fichier : 349_901.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


• Do NOT clean glass when hot. • Turn off appliance after 3-4 hours of operation and ALLOW TO COOL. • Remove and clean glass assembly. • Replace glass assembly and operate appliance for additional 12 hours. Refer to maintenance instructions. WARNING Inspect external vent cap regularly. • Ensure no debris blocks cap. • Combustible materials blocking cap may ignite. • Restricted air flow affects burner operation. Heat & Glo • Supreme-XTS, Grand-XTS • 349-901 Rev. i • 12/09 Inspect Maintenance Tasks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary. Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary. 3. Verify no obstructions to airflow through the louvers. 4. Verify maintenance of proper clearance to combustible household objects. Gasket Seal, Glass Assembly and Glass 1. Inspect gasket seal and its condition. 2. Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat. 3. Confirm there is no damage to glass or glass frame. Replace as necessary. 4. Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact and operating properly. Replace as necessary. 5. Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed. Valve Compartment and Firebox Top 1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. 2. Remove any foreign objects. 3. Verify unobstructed air circulation. Logs 1. Inspect for broken, damaged, or missing logs. Replace as necessary. 2. Verify correct log placement and no flame impingement causing sooting. Correct as necessary. Firebox 1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary. 2. Replace appliance if firebox has been perforated. Burner Ignition and Operation 1. Verify burner is properly secured and aligned with pilot or igniter. 2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary. 3. Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths. 4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay. 5. Inspect for lifting or other fl ame problems. 6. Verify air shutter is clear of dust and debris. 7. Inspect orifice for soot, dirt or corrosion. 8. Verify manifold and inlet pressures. Adjust regulator as required. 9. Inspect pilot flame strength. Clean or replace orifice as necessary. 10. Inspect thermocouple/thermopile for soot, corrosion and deterioration. Clean with emery cloth or replace as required. 11. Verify millivolt output. Replace as necessary. Venting 1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc. 2. Confirm that termination cap remains clear and unobstructed by plants, etc. 3. Verify that termination cap clearance to subsequent construction (building additions, decks, fences or sheds) has been maintained. 4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and flashing remains intact. 6. Inspect draft shield to verify it is not bent, damaged or missing. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Heat & Glo • Supreme-XTS, Grand-XTS • 349-901 Rev. i • 12/09 36 Heat & Glo • Supreme-XTS, Grand-XTS • 349-901 Rev. i • 12/09 Figure 15.1 Appliance Dimensions 15 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3. A C B ELECTRICAL GAS INLET ACCESS D E F G H I L N K J M O P Q R S U T MODEL DIMENSIONS LOCATION Grand-XTS Supreme-XTS Inches Millimeters Inches Millimeters A 33-1/32 839 29-1/32 737 B 24-1/4 616 20-5/32 512 C 12-1/8 308 10-3/32 256 D 36-7/8 937 32-5/16 821 E 32 813 27-25/32 706 F 14-3/4 375 12-7/16 316 G 27 686 22-23/32 577 H 22-3/4 578 20-1/4 514 I 23-11/16 602 21-5/32 537 J 8-7/16 REF 215 8-7/16 REF 215 MODEL DIMENSIONS LOCATION Grand-XTS Supreme-XTS Inches Millimeters Inches Millimeters K 2-5/16 58 2-5/16 58 L 4-7/16 112 4-7/16 112 M 5-5/32 131 5-5/32 131 N 2-5/32 55 2-5/32 55 O 13-23/32 348 13-23/32 348 P 2-17/32 64 2-17/32 64 Q 5-9/32 135 5-9/32 135 R 8-29/32 227 8-29/32 227 S 14-11/16 373 14-11/16 373 T 2-19/32 66 2-19/32 66 U 6-1/16 154 6-1/16 154 Heat & Glo • Supreme-XTS, Grand-XTS • 349-901 Rev. i • 12/09 37 B. Vent Kits Components Direct Vent Flex Liner Kits (see Figure 15.2) LINK-DV-30B or (LINK-DV-30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter. LINK-DV4-30B or (LINK-DV4-30): Mas...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - GRAND-XTS (3.15 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories