V. Electric supply ¦ The mains connection can either be mounted above or below. At least 40 mm of the connecting cord’s insulating jacket must be clamped inside the appliance. VI. Startup ¦ For low water line pressure, remove the flow limiter (see Supplementary Information A). ¦ Instruct the user with regard to the operation of the instantaneous water heater. ¦ Separate the required language version from the rest of the operating instructions. This can be kept in the swing- out control panel of the instantaneous water heater. Additional information A B If the flow-through heater does not achieve adequate flow as a result of water line pressure that is too low in your house installation, remove the flow limiter. Priority circuit for the combination with electrostorage heating units: For operation with the priority circuit, a special load reducing relay (special accessory) is required. Other already existing load reducing relays with the exception of electronic load reducing relays could cause malfunctions. C Status Indicator in the Heater LED Heater Status Off Off On Ready Slow blinking (1/s) Heating (Highlight) 4 GB GB Specifications Rated power [kW] 18 21 24 Rated voltage 380 – 415 V 380 – 415 V 380 – 415 V Warm Water Quantity at Rated Power for temperature increases of: 12 °C to 38 °C 12 °C to 60 °C Switch-on quantity Switch-on flow pressure* [l/min] [l/min] [l/min] [MPa (bar)] 9.9 5.4 2.6 0.025 (0.25) 11.6 6.3 2.6 0.025 (0.25) 13.2 7.2 2.6 0.025 (0.25) Flow pressure (at rated power and 60 °C)* With flow limiter Without flow limiter Operative range in waters of specific electric resistance at 15 °C Rated pressure Maximum permissible supply temperature [MPa (bar)] [MPa (bar)] [.cm] [MPa (bar)] [°C] 0.028 (0.28) 0.013 (0.13) . 1300 1 (10) 20 0.035 (0.35) 0.020 (0.20) . 1300 1 (10) 20 0.048 (0.48) 0.026 (0.26) . 1300 1 (10) 20 Maximum mains impedance at connection site [.] – – . 0.41 * Plus any pressure loss at the tap mixer G12A4721421512362010033242388 Special accessories ¦ DLE 02RBS Pipe set: When using the instantaneous water heater as a built-under appliance. ¦ Priority switch (load reducing relay): For operation with the priority circuit. ¦ DLE 02AP Mounting set: For surface-mount installation. (Highlight) 5 4. 4. 3. I. 5. 1. 1. 2. II. 100 1. 2. 3. 4. 388 ca. 96 70 44 100 ca. 72 332 5. III. III. max. 17 mm max. 31 mm ca. 2 mm ca. 16 mm 1. 4. 3. 2. IV. 4. 2. 2. 3. 4. 6. 7. 1. 5. 1 Minute entluften! Vent for one minute! Aerer pendant 1 minute ! 1 minuut ontluchten! .Purgar durante 1 minuto! Odpowietrzac 1 minut.! warm hot chaud warm caliente ciep.y V. min. 40 mm 0 mm 1. 2. RESET L1L2L3PE PE L3 L2 L1 min. 40 mm 6. 5. 3. 4. LED L 3 L 2 L 1 PE 3 2 1 PE 2. 1. 3. VI. . A B C 3. 1. 4. 2. 5. 6. 7. 8. de Entsorgung Dieses Gerat ist entsprechend der europaischen Richtlinie 2002/96/EG uber Elektro- und Elektronik-Altgerate (waste electrical and electronic equipment – WEEE) gekennzeichnet. Die Richtlinie gibt den Rahmen fur eine EU-weit gultige Rucknahme...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - DEE 1802 (931.72 kb)
Chauffe-eau - DEE 2402 (931.72 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories