|
Facilité d'utilisation
¦ Repairs to the appliance may only be undertaken by a suitably qualified specialist. I. Preparations for installation ¦ The appliance and the respective water pipes and components may only be installed in a frost-free room. II. Wall mounting (Fig. B) ¦ A special supporting structure may be necessary when installing the appliance on a light-weight wall. ¦ After mounting the tank, use the adjustable screws to vertically align the tank. ¦ A mounting template is printed on the appliance packaging to facilitate installation. ¦ Use suitable screws with at least O 8 mm (supplied) III. Supply of water ¦ Use detachable connections only. Closed circuit operation (pressure-resistant) (Fig. C) ¦ This tank can be used to supply several taps. A type-tested diaphragm-type safety valve B manometer test nozzle C check valve D test device for check valve E pressure reducing valve F stop valve Gtap fittings H drain valve ¦ Important: The standards and regulations and/or properties of the water tank and the accessory parts differ from country to country and must be observed accordingly. ¦ Rinse the water pipes thoroughly to remove impurities and contaminants before connecting the taps. ¦ Install the appliance in the vicinity of the tap at which most warm water is taken. ¦ Install a safety valve combination. ¦ If the permissible water pressure is exceeded (see table with Technical data), an additional pressure-reduction valve must be installed and set accordingly. ¦ Install the pressure reduction valve away from the tank. ¦ Do not install a cut-off valve between the safety assemblies and the tank. ¦ An outlet must be installed under the safety valve as expansion water can drip from the valve. ¦ The safety valve outlet must always be open. ¦ The safety valve combination must be authorized for closed (pressurized) operation (type-tested). ¦ If the safety valve is not directly situated before an outlet, an outlet pipe with a continuous downwards tilt must be fitted. ¦ Note: According to the energy conservation regulations, the temperature in pipes may not exceed 60 °C if the length of the warm water pipes exceeds 5 m. 7 GB GB Unpressurized operation ¦ With this tank one open (unpressurized) tap can be supplied. ¦ Install a suitable overflow mixer: BZ12410 Wall mixing tap with tub outlet, shower hose and hand-held shower head: or BZ11110 Mixing tap with visible cross-connected body for mounting on vertical surface and hand-held shower head. ¦ The tap outlet must always remain free as it is used for ventilation. Do not use perlators/diffusers. ¦ Install a check valve in the cold water supply. IV. Startup (Fig. E, F) Important: Connect the water supply connections and then the electrical supply connections as otherwise the appliance will be damaged. ¦ Fill and rinse the tank until the water flows without air bubbles. ¦ Plug in the main plug, the LED of the operational display (4) lights up red. The tank is in frost protection mode, on the display the actual water temperat...
Ce manuel est également adapté pour les modèles :Chauffe-eau - DG10035P/01 (464.32 kb)
Chauffe-eau - DG10035R/01 (464.32 kb)
Chauffe-eau - DG30035E/01 (464.32 kb)
Chauffe-eau - DG30035P/01 (464.32 kb)