|
Facilité d'utilisation
READ CAREFULLY THE PRODUCT INSTALLATION, OPERATING AND MAINTENANCE MANUAL. FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY. THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES, FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE. THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS PROPERTY DAMAGE. The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical Toxicology of Commercial Products, 5th edition. The pressure of the heat transfer medium must be limited to 30 PSIG by an approved safety or relief valve. Part #: 9040-586 (07/08) 1. TABLE OF CONTENTS 2. Pre-Installation Checklist .................................................2 3. Required Components and Accessories Checklist.........3 4. WH-7 & 9 Classic Series Piping Installation....................4 5. Top Down™ TD-Series Piping Installation ......................6 6. Ready-To-Run RTR-Series Piping Installation ................8 7. WHS Premier Series Piping Installation........................ 10 8. Wiring All Smart Control™ Models............................... 12 9. Wiring All Dial Control Models (Except RTR Models) ......... 20 10. Wiring All Ready-To-Run (RTR) Models ....................... 23 11. Startup Procedure For All Models ................................ 25 12. Setting the Smart Control™.......................................... 26 13. Troubleshooting............................................................. 27 14. Replacement Parts........................................................ 28 15. Cleaning the BoilerMate® Heat Exchanger................... 29 16. General Safety Information ........................................... 30 2. PRE-INSTALLATION CHECKLIST IMPORTANT STEPS AND DECISIONS REQUIRED BEFORE INSTALLATION M THIS PRODUCT MUST BE INSTALLED AND MAINTAINED BY A LICENSED PROFESSIONAL. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND STATE CODES OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND THE NATIONAL ELECTRIC CODE. M DRIP PAN AND DRAIN: This appliance should not be installed in an area where leakage of the tank or connections can result in damage to the area adjacent to the appliance or to lower floors of the structure. When such locations cannot be avoided, a suitable drain pan, adequately drained and kept clear, must be installed under the appliance. M CAUTION: Determine whether your water is corrosive or acidic, and that there are no suspended solids, toxic or other substances or abnormally high chlorine levels in the water that could damage or affect the BOILERMATE® or the rest of your plumbing system. USE GLYCOL ONLY WITH DOUBLE-WALLED HEAT EXCHANGER MODELS. Glycol is a hazardous substance. To avoid seepage or leakage of glycol to surfaces where humans or animals can ingest it, use glycol only in double-walled units, so that any leaks will most likely be released to the atmosphere. However, a leak to a surface area may still occur, so any use of glycol must be monitored closely and humans and animals should be protected from contact with the unit. Do not connect the BOILERMATE® domestic supply with baseboard or other space heating units or elements. Any contaminants in the baseboard units will contaminate the potable water in the BOILERMATE® and also adversely affect its performance. M Wiring Options. Select either a Non-Priority or Priority System: Two options are available when wiring the controls of the BOILERMATE® in the space heating system (boiler and distribution elements). 1. Non-Priority System -The controls of the BOILERMATE® must be wired as a separate heating zone with a standard zone valve or a separate circulator dedicated to the BOILERMATE® “zone”. NOTICE: In this non-priority option, the BOILERMATE® will be supplied just as another zone. This means that if all space heating zones call for hot boiler water at the same time, the BOILERMATE® may not be supplied with enough hot boiler water to “recover” adequately. The delivery of domestic hot water will be diminished. In many, but not all cases, this is not a problem because the routine oversizing of boiler output is adequate for both loads. 2. Priority System -Under this wiring option the BOILERMATE® will be supplied before space heating. In limited circumstances, space heating can be lost in the home in this priority mode. Any demand for space heating is postponed until the BOILERMATE® has reached its set temperature. This delay in supplying the space heating zones is usually not noticed by the inhabitants of the livin...
Ce manuel est également adapté pour les modèles :Chauffe-eau - BoilerMate Top Down (4.6 mb)
Chauffe-eau - WH-7 Classic Series (4.6 mb)
Chauffe-eau - WH-9 Classic Series (4.6 mb)