Instructions Baxi Potterton, Modèle BAXI COMBI INSTANT 105 HE

Fabricant : Baxi Potterton
Taille : 1.07 mb
Nom Fichier : Baxi_Combi_Instant_HE_User_Instructions.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


In IE, this must be carried out by a competent person as stated in I.S. 813 “Domestic Gas Installations”. Lifting -This product should be lifted and handled by two people. Stooping should be avoided and protective equipment worn where necessary. Carrying & lifting equipment should be used as required, e.g. when installing in a loft space. The addition of anything that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations. Warning -Check the information on the data plate is compatible with local supply conditions. Benchmark Commissioning Checklist Please ensure that your installer hands you the boiler Installation & Servicing Instructions with the Benchmark Commissioning Checklist sections completed. The details in the Checklist will be required in the event of any warranty work. Keep the instructions in a safe place and ensure that the Service Interval Record at the back is completed at each service visit. All CORGI registered installers carry a CORGI identification card and have a registration number. You can check your installer is registered by telephoning 0870 4012300 or writing to: 1 Elmwood, Chineham Business Park, Crockford Lane, Basingstoke. RG24 8WG or check online at Baxi declare that no substances harmful to health are contained in the appliance or used during appliance manufacture. The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force, and only used in a suitably ventilated location. In GB, the installation must be carried out by a CORGI Registered Installer. It must be carried out in accordance with the relevant requirements of the: • Gas Safety (Installation & Use) Regulations. • The appropriate Building Regulations either The Building Regulations, The Building Regulations (Scotland), Building Regulations (Northern Ireland). • The Water Fittings Regulations or Water Byelaws in Scotland. • The Current I.E.E. Wiring Regulations. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. In IE, the installation must be carried out by a competent Person and installed in accordance with the current edition of I.S. 813 ‘Domestic Gas Installations’, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. All systems must be thoroughly flushed and treated with inhibitor. Codes of Practice, most recent version should be used In GB the following Codes of Practice apply: Standard Scope BS 6891 Gas Installation. BS 5546 Installation of hot water supplies for domestic purposes. BS 5449 Forced circulation hot water systems. BS 6798 Installation of gas fired hot water boilers. BS 5440 Part 1 Flues. BS 5440 Part 2 Ventilation. BS 7074 Expansion vessels and ancillary equipment for sealed water systems. BS 7593 Treatment of water in domestic hot water central heating systems. In IE the following Codes of Practice apply: Standard Scope I.S. 813 Domestic Gas Installations. The following BS standards give valuable additional information; BS 5546 Installation of hot water supplies for domestic purposes. BS 5449 Forced circulation hot water systems. BS 7074 Expansion vessels and ancillary equipment for sealed water systems. BS 7593 Treatment of water in domestic hot water central heating systems. 1.0 Warnings 1.0 Warnings 1.1 In an Emergency Gas Tap If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; 1. Turn off the electrical supply and turn the selector switch on the facia box to the OFF position. 2. Using a suitable open ended spanner or screwdriver turn the square on the gas tap to the left to isolate the gas supply at the boiler (Fig. 1). 3. The isolating valves are positioned under the boiler and can be closed by turning their taps to the right towards the wall (Fig. 2). Fig. 1 4. Call your Installer or Service Engineer as soon as possible. Fig. 2 1.2 In case of gas leaks 1. If a gas leak is found or suspected, turn off the gas supply at the meter immediately and at the isolating valve on the boiler if possible. Contact your Gas Supplier immediately. 1.3 Servicing your Appliance 1. For reasons of safety and economy your appliance should be serviced annually. Servicing must be performed by a competent person. Your Installer or Service Engineer will be able to advise you. 2. Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction. 1.4 Electricity Supply 1. THIS APPLIANCE MUST BE EARTHED. 2. A standard 230V ~ 50Hz supply is required. The appliance must be protected by a 3 amp fuse. Heating Flow, Heating Return andMains Water InletIsolating Valves Never Hang Flammable Items Over The Appliance Hinged Lower Door...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - BAXI COMBI INSTANT 80 HE (1.07 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories