Facilité d'utilisation


The heating will operate when the white tappets are set to the outer edge of the bezel. To ensure the heating stays OFF set the required tappets inwards towards the centre of the bezel. Each tappet represents 15 minutes. For example: If the heating is not required between 10 A.M. and 11 A.M. the four tappets anticlockwise from the 10 A.M. will be set inwards (Fig. 7). 2 3 4 5 AM 7 8 9 10 0 9 10 11 12 4 Constant Time Pointer Timed Off Rotate to adjust time Off Position On Position Time Pointer Fig. 6 Fig. 7 8.0 Emergency Warning ! If you smell gas Turn off the gas supply at the meter and call your gas supplier immediately. It is possible to isolate the boiler at the isolating valve (Fig. 8). In GB, Transco operate a 24 hour emergency service and the telephone number will be listed in your telephone directory. Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person. Gas Tap Fig. 8 Heating Flow, Heating Return and Mains Water Inlet Isolating Valves In an Emergency If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; 1. Using a suitable open ended spanner, turn the square nut on the gas tap through 90° (1/4 turn) to isolate the gas supply at the boiler (Fig. 8). 2. The water isolating valves are positioned under the boiler and can be closed by turning their taps to the right towards the wall (Fig. 8). 3. Call your Installer or Service Engineer as soon as possible. © Baxi Heating UK Ltd 2008 9.0 Warranty & Service © Baxi Heating UK Ltd 2008 UK Comp No 5116283 - Iss 6 - 4/08 Information Label All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. Serial Number Date of Installation Installer Details (name, address and contact number(s)) Please complete the boxes below D D M M Y Y Standard Warranty Term & Conditions 3 Years Free Warranty - register today To receive your 3 years free warranty please complete the form supplied with the boiler or simply call heateam, the service of Baxi Heating UK Ltd on 08706 017 017. Our promise to you If you experience a fault with your new boiler, we aim to provide a safe and high quality repair service supported by our dedicated national network of highly skilled engineers. If your installer can’t resolve the problem for you, we will do everything we can to get an engineer out to you as quickly as possible. Nothing in this warranty will affect your statutory consumer rights. What you need to do if you experience a problem with your heating system or the operation of the boiler You should always contact your installer first, because the fault may not be related to the boiler. If your installer confirms that the fault is within the boiler itself and he/she can’t repair it, our friendly customer service team is on hand to help. Simply call our service division heateam on 08706 017 017 to book an engineer visit or for any general advice that you may need. Our contact centre is open Monday to Friday 8am - 6pm, weekends and Bank Holidays 8.30am - 2pm, excluding Christmas Day and New Years Day. When calling heateam it would be helpful if you could have the following information to hand:- 1 boiler serial number (see opposite). 2 boiler make and model number. 3 Your installer name and address details. 4 Proof of purchase (if you do not have the boiler serial number). What this warranty covers Free of charge repair or replacement of components found to be faulty from manufacture. Free of charge replacement of the complete unit provided always that the failure is related to a manufacturing fault that cannot be repaired or is uneconomic to repair. The warranty runs for 3 years from the date your product is installed. What this warranty does not cover Repairs to boilers which haven’t been installed and commissioned properly, and as set out in the installation instructions (this includes the need to flush the system effectively and add a suitable corrosion inhibitor). Any damage caused by hard water scale deposits and/or aggressive water resulting from corrosion. Any other defects or failures, either in the connected heating system or outside of the boiler itself. Faults caused by inadequate supply of electricity, gas or water to the property. Installations within commercial settings for which this boiler was not designed. Reimbursement of any third party repair or replacement costs that we haven’t been told about or agreed with you in advance. Compensation for consequential losses (e.g. loss of earnings, business losses, stress and inconvenience) arising from a production breakdown, including repair delays caused by factors outside our reasonable control. Annual Service T...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories