550-110-440/0584WP INSTALLATION OUTLINE and TABLE OF CONTENTS Section I: Pre-Installation Considerations Page Air supply....................................... 3 Clearances...................................... 3 Foundation...................................... 3 Page Placement ...................................... 4 Hydrostatic test .................................. 4 Jacket assembly.................................. 4 Water piping connections ....................................................4 Multiple zoning-circulators................................................4 Multiple zoning-zone valves..............................................4 Freeze protection ..............................................................4 By-pass piping ..................................................................5 Low Water cut-off..............................................................5 ASME approval..................................................................5 Relief valve piping ............................................................5 Expansion tank and air vent..............................................5 Minimum pipe sizes ..........................................................5 Piping schematic ..............................................................5 Steam piping connections ....................................................6 Equalizer............................................................................6 Relief valve piping ............................................................6 Minimum pipe sizes ..........................................................6 Piping schematic ..............................................................6 Replacement steam boiler piping for one-pipe systems ..............................................................6 Page Tankless heaters—water boilers..................... 7 Tankless heaters—steam boilers..................... 7 Storage heaters—water boilers only.................. 7 Section V: Non-packaged Boilers—Controls & Burner Page Tapping table.................................... 8 Water boiler controls .............................. 8 Steam boiler controls.............................. 8 Oil burner....................................... 9 Page Chimney or vent requirements....................... 9 Breeching erection................................ 9 Barometric draft control............................ 9 Page Wiring.......................................... 10 Fuel line piping................................... 10 Page Fill the system ...................................-10 Burner adjustment (use combustion test equipment)................................. 10 Skimming steam boilers ........................... 10 READ ALL INSTRUCTIONS BEFORE STARTING FAILURE TO COMPLY WITH INSTALLATION INSTRUCTIONS CAN VOID WARRANTY IMPORTANT: When calling or writing about the boiler, PLEASE GIVE THE MODEL, SERIES, AND C.P. NUMBERS located on the boiler rating nameplate. Any reuse or reproduction of the artwork and copy in this manual is strictly prohibited without the written con' sent of Weil-McLain. ORDER BURNER PARTS Dl RECTLY FROM BURNER MANUFACTURER. The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels, or to important information concerning the life of the product. An explanation of each term is given below. DANGER Danger is used to indicate the presence of a hazard which will cause severe personal injury, death or substantial property damage if the warning is ignored. WARNING Warning is used to indicate the presence of a hazard which can cause severe personal injury, death or substantial property damage if the warning is ignored. CAUTION Caution is used to indicate the presence of a hazard which will or can cause minor personal injury or property damage if the warning is ignored. NOTICE Notice is used to notify of special instructions on installation, operation or maintenance which are important but not related to personal injury hazards. Section I: Pre-Installation Installations must comply with all local codes, laws, regulations and ordinances. When required, the installations must conform to American Society of Mechanical Engineers Safety Devices for Automatically Fired Boilers, No. CSD-1. In Canada the installation must comply with Canadian Standards Association CSA B149, Installation Code for Oil Burning Equipment, and any local or provincial codes that may apply- AIR SUPPLY FOR COMBUSTION RESIDENTIAL GARAGE INSTALLATION WARNING Adequate combustion and ventilation air must be provided to assure proper combustion. AN EXHAUST FAN MUST NOT BE USED IN THE BOILER ROOM AREA. 1. Conventional buildings—unconfined rooms: a) Infiltration will normally provide enough air. 2. Confined room OR boiler room without an outside wall: a) A fresh air opening to the outside must be provided. . 1) Free cross secti...
Ce manuel est également adapté pour les modèles :Chauffe-eau - B-66HE (1.27 mb)