Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions Electrolux, Modèle EWH-ECO R/RN

Fabricant : Electrolux
Taille : 299.32 kb
Nom Fichier : 7231700en.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Installation and first operation of the storage heater and the fittings have to be done by an expert which can take the responsibility for properly done work and explains the handling procedures. For the connection the specific technical conditions of the energy supplier as well as the valid standards and safety regulations have to be considered. WALL MOUNTING PROCEDURE Hot water 6 Use 4 adequately resistant and sturdy screws and rawl- Safety 1 plugs capable of holding the weight of the filled heater. 2 Min. 20 mm air inlet 50 cm valve Cold water 3 LOCATION 4 5 The installation procedure is greatly facilitated by the possibility to locate the unit horizontally (EWH-SL/SLN and EWH-R/RN) or vertically in a frost-free (!) place anywhere the house. It would be a good idea to place the unit as close as possible to the outlet - short piping means little loss of temperature. 50 cm A minimum space of 50 cm below the outlet pipe is necessary Hot water 6 for servicing. As shown in the drawing the input and output pipes must be 6 on the left side when the heater is installed horizontally. Should the unit be close to a wall leave the recommended minimum-space for maintenance and service. Do not install the heater with its wall mounts against the floor nor on a horizontal plane. Min. 20 mm air inlet 21 Safety valve 3 45 Cold water HYDRAULIC INSTALLATION The heater must be connected to the water supply mains. a) The safety valve - supplied with the heater- MUST be installed on the cold water input (see right side) -Before connecting the safety valve with the heater, the connecting pipe must be rinsed carefully. -The draining pipe and the safety valve must be left open to the air and be installed in a continuous downward slope. Water expands when heated. The units of the series R, eco R and SL are supplied with a safety valve that lets the expanding water flow back into the cold-water feed. The units of the series RN and SLN have a safety valve that prevents the expanding water (N=non return) from flowing back into the cold-water feed. Here a suitable siphon for the absorption of the expanding water is to install. The drain of the safety valve must not be blocked. To open the safety valve (not safety valve eco) to let the water flow from the heater - via the outlet - turn the knob clockwise or counterclockwise as you please. The proper operating of the safety valve should be tested periodically that way: -turn the knob clockwise or counterclockwise up to the top position -the water should flow out of the passage -turn the knob to its down position The pressure rating is indicated on the knob. b) If the water-supply pressure exceeds 5 bar, a type-approved reducing valve must be installed. 1. Safety valve 2. Turning knob for cleaning and draining 3. Draining pipe for the safety valve 4. Stop valve 5. Reducing valve - necessary when pressure is more than 5 bar- to be installed after the “meter” 6. Earthed plastic sleeves (supplied with the heater) ELECTRIC INSTALL...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - EWH-R/RN (299.32 kb)
Chauffe-eau - EWH-S/SN (299.32 kb)
Chauffe-eau - EWH-SL/SLN (299.32 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories