|
Facilité d'utilisation
GAS-FIRED POWER BURNE. FOR DOMESTIC HOT WATE. . INSTALLATION . OPERATION . SERVICE . MAINTENANCE . LIMITED WARRANT. WARNING: If the information in theseinstructions is not followed exactly, a fireor explosion may result causing propertydamage, personal injury or death. . Do not store or use gasoline or othe. flammable vapors and liquids in th. vicinity of this or any other appliance. . WHAT TO DO IF YOU SMELL GAS. . Do not try to light any appliance. . Do not touch any electrical switch. do not use any phone in you. building. . Immediately call your gas supplie. from a neighbor's phone. Follow th. gas supplier's instructions. . If you cannot reach your gas supplier. call the fire department. . Installation and service must b. performed by a qualified installer. service agency or the gas supplier. Thank you for buying this energy efficient water heater fro. A.O. Smith Water Products Company. We appreciate you. confidence in our products. CAUTIO. TEXT PRINTED OR OUTLINED IN RED CONTAIN. INFORMATION RELATIVE TO YOUR SAFETY. PLEAS. READ THOROUGHLY BEFORE INSTALLING AND USIN. THIS APPLIANCE. PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AN. A DIVISION OF A.O. SMITH CORPORATIO. NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. Mc BEE, SOUTH CAROLIN. PRINTED IN U.S.A. 2570 1199 Part No. 194119-000 Supersedes P/Ns. 192968-000/193329-000/193311-000 ROUGH-IN -DIMENSIONS CYCLONE XHE BTH 120 - 250 Table 1. RECOVERY CAPACITIES - NATURAL GAS / L.P. Mode. BT. Inpu. Approx. Gallo. Capacit. TEMPERATURE RISE - DEGREES °F - GALLONS PER HOUR 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. BTH - 12. 125,000 Nat. 6. 47. 35. 28. 23. 20. 17. 15. 14. 12. 11. 11. 10. BTH - 12. 120,000. L.P. 6. 45. 34. 27. 22. 19. 17. 15. 13. 12. 11. 10. 9. BTH - 15. 150,000 Nat. 10. 57. 42. 34. 28. 24. 21. 19. 17. 15. 14. 13. 12. BTH - 15. 150,000. L.P. 10. 57. 42. 34. 28. 24. 21. 19. 17. 15. 14. 13. 12. BTH - 19. 199,900 Nat. 10. 75. 56. 45. 38. 32. 28. 25. 22. 20. 19. 17. 16. BTH - 19. 199,900. L.P. 10. 75. 56. 45. 38. 32. 28. 25. 22. 20. 19. 17. 16. BTH - 25. 240,000 Nat. 10. 91. 68. 54. 45. 39. 34. 30. 27. 24. 22. 21. 19. Recovery capacities are based on heater performance at 94% thermal efficiency. 2 FOREWOR. These designs comply with the latest version of the American Nationa. Standard for Gas Water Heaters, Volume III, ANSI Z21.10.3 as an automati. circulating tank water heater, and automatic storage water heaters. Detailed installation diagrams are found in this manual. These diagrams wil. serve to provide the installer with a reference for the materials and method. of piping necessary. It is highly essential that all water, gas piping an. wiring be installed as shown on the diagrams. Particular attention should be given to the installation of thermometers a. the locations indicated on the diagrams as these are necessary for checkin. the proper functioning of the heater. In addition to these instructions, the equipment shall be installed i. accordance with those installation regulations in force in the local are. where the installation is to be made. These shall be carefully followed in al. cases. Authorities having jurisdiction should be consulted befor. installations are made. In the absence of local codes, the installation must comply with the lates. editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and th. National Electric Code, NFPA 70. The former is available from th. Canadian Standards Association, 8501 East Pleasant Valley Road. Cleveland, OH 44131, and both documents are available from the Nationa. Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269. TABLE OF CONTENT. PAG. PAG. ROUGH-IN DIMENSION. ................................................................... . Water Line Connection. .................................................................. 1. FOREWOR. ....................................................................................... . Heater Wirin. .................................................................................. 1. FEATURE. ........................................................................................... . OPERATIO. ......................................................................................... 1. Water Temperature Contro. ............................................................. . Sequence of Operatio. ................................................................... 1. High Limit Switch (E.C.O.. .............................................................. . Self Diagnostic Controlle. ............................................................... 1. Dishwashing Machine Requiremen. ................................................ . Gas Value LEDs Flashin. ............................................................... 1. Circulating Pum. ............................................................................. . Error Code. ..................................................................................... 1. INSTALLATION INSTRUCTION. ...................
Ce manuel est également adapté pour les modèles :Chauffe-eau - BTH 120 - 250 (856.74 kb)
Chauffe-eau - BTH 120 - 250 (856.74 kb)