Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Haier, Modèle FCD-JTHA40-III, FCD-JTHA50-III, FCD-JTHA60-III

Fabricant : Haier
Taille : 1.71 mb
Nom Fichier : 2d02a063-af99-4593-ba79-41efa8b543f6.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This water heater shall only be repaired and maintained by qualified servicemen. Improper maintenance may cause severe injury or damage. Before opening or repairing water heater, please do pull out the power plug. External Cleaning: Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a little of mild detergent. Do not use gasoline or other solvents. Finally dry with dry cloth. Keep water heater dry. Do not use cleansers containing grinding agent (e.g. toothpaste), acids, chemical solvents (e.g. alcohol) or polishers to clean. Statement: Note: Before asking for service, please refer to troubleshooting section to resolve easy problems. Cleaning and Maintenance Internal Cleaning: To ensure high working efficiency, heating elements and tank liner of water heater shall be cleaned once in three years. Take care not to damage protection layer on heating elements and tank liner inner surface. According to different local water qualities and use habits, magnesium rod shall be periodically replaced. If maintenance is needed, please contact local service station. Problems No outlet water Heating lamp lighted Heating lamp not lighted Outlet water is cold Heating lamp keep lighted for long Outlet water flow and temperature is not steady Possible Causes to be Confirmed If water supply is stopped or water pressure is too low If use point is blocked or if hot water valve is open If heating element is damaged If power is connected If thermostat is out of work Water hasn't reached temperature setting If thermostat is out of work If city water pressure is steady Corrective Measures Check Check and clean Contact service station Connect power Contact service station Continue heating Contact service station Check FAQ Dimensions 3 Electric Circuit Diagram (Figure 1) Front view Cutaway view Bottom view Model Volume Net weight a1 b1 c1 d1 e1 A Hot water outlet B Cold water inlet C Heating element D Enamel tank E Wall-mounting bracket f1 a1 b1 e1 D E E C C1 d1 f1 FCDJTHA60- (E) 60L 22.8kg 802 mm 444 mm 100 mm 335 mm 390 mm 197mm FCD- 50L 20kg 702 mm 444 mm 100 mm 235 mm 390 mm 197 mm JTHA50- (E) 40L 18.5kg 673mm 391mm 100mm 220mm 365mm 197mm FCDJTHA40- (E) A B Remarks:the permitted error limit of above parameters is 10%. L N E BT HL EH E L:Brown wire MT N:Blue wire MT: High temperature limiter BT: Thermostat HL:Heating indicator EH:Heating element E:Yellow/green wire Parameters Rated voltage: 220V~,50Hz Dimension: (See to Figure 1) Power: 1500W Weight: (See to Figure 1) Rated pressure: 0.65 / 0.75MPa Volume: (See to Figure 1) Waterproof grade: IPX 4 ( ) Tap water pressure: no less than 0.05MPa For the first use after installation, due to there's no water within the tank, first the city water inlet valve and mixing valve must be opened. Close the mixing valve when water flows out continuously from the showerhead or other outlets (the tank is full). Check connections are free of water leakage, and insert the power plug. Turn the knob to set your desired water heating temperature, which can be stepless changed between cold water inlet temperature and 75 . In heating mode, heating lamp is lighted on. Normally the knob shall be positioned at highest temperature. This machine has a thermostat function, which automatically switches off the water heater when temperature reaches the setting value, and switch on again when water temperature decreases to certain value. City water pressure 0.75 MPa will cause much water flowing out from safety valve pressure relief vent. This is due to too high water pressure. Please ask after-sales service for correction. The rated pressure of FCD-JTHA40- (E) is 0.65 MPa Operation Instructions To avoid causing machine troubles, do not connect power before tank is full of water. Adjust a suitable temperature before use, for water temperature above 50 may burn your skin. This product is closed water heater, which can supply hot water through pipe connection to several points like bathroom (bathtub, washbasin, showerhead) and kitchen. Heating adjustment can be made flexibly all year round adapting to climate changes. In long-term out-of-use or maintenance, you can close city water pipe valve, open mixing valve to hot water range, and move up safety valve handle to drain the tank. To avoid injury, before next use, it is suggested to first open hot water valve before switching on the water heater, exhausting gas possibly retained in the pipeline. In this case, no smoke or fire is permitted near the open valve. Carefully check and confirm all parts are in good condition. Provided hot water quantity can meet use demand, temperature setting shall be possibly low. It can minimize heat dissipation, high-temperature corrosion and sedimentation, ensuring a longer service life. Regularly ask servicemen to make safety inspection, remove sediment on heating elements, and check consumption of anode bar. Too much consumed anode bar shall be replaced. 1. 2. 3. 4. 5. 6. Attentions in Operation Attenti...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - Little Sea-ox FCD JTHA40-III(E), FCD-JTHA50-III(E), FCD-JTHA60-III(E) (1.71 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories