Facilité d'utilisation
The hose can be cut short or extended as necessary. To avoid splash, the hose shall be installed as inclined downward. Fix the showerhead holder at a suitable place on the wall, and place the showerhead on the holder. After making sure the tank is full of water, connections show no water leakage and power supply complies with requirement, connect the power supply and make trial operation. (Fig.4) (Fig.5) Pressure Relief Vent During installation, adequate space must be reserved for future maintenance and repair. If the water heater is installed within decoration boards, the right board shall be removable to facilitate removing the plastic cover during maintenance. City water inlet pressure shall not be less than 0.05 Mpa. Electric water heater shall be installed indoors with ambient temperature above 0 . The pipes shall be collectively laid. Hot water outlet shall not be too far from use points. In case farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat loss. The mounting wall shall be firm and reliable to support twice the weight of water heater full of water. Non-load bearing walls or air brick walls must have corresponding protective measures like additional support, wall-through screws or back boards. Electric water heater shall be located in a place easy for use, maintenance and with a floor drainer. In case the tank or pipes leak, nearby or lower facilities shall not be damaged. The installation location shall avoid being above toilet bowl, bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling to users. Power socket for water heater shall be in a dry place free of water splash. (splashproof box is preferred) Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated position with no random modification. The safety valve pressure relief vent shall keep open to the air. Do not block it. Installation Attentions in Installation Safety Precautions Haier C Symbol Denotation Do not proceed! Wrong operation may cause fatal injury or death. Do follow the instructions! Wrong operation may cause human injury or house property loss. The product adopts Haier Safe Care patented technology. In normal installation, even in severe case that ground wire is live due to wrong connection, the product Safe Care technology can filter and efficiently ensure your safety. However, whenever your feel a sensory current, please pull out the power plug and notify local after-service men in time. Do not dismantle by yourself. In winter in cold regions, for long-term outof- use, please lift the safety valve handle to empty the water, avoiding ice formation damaging the water heater. Damaged power cord must be replaced by after-service technicians with special cable (factory provided). Other persons shall not dismantle or repair. In addition, do not place flammable matters nearby the water heater. Check if power meter and wire size are consistent with water heater rated current. If necessary, ask experienced qualified electricians to check. The water heater shall use a.c. 220 V / 50 Hz power supply from a separate socket (no multi-purpose socket) and be reliably grounded. The power socket shall meet national standard requirements. Power plug pins shall be cleaned in time to avoid any contamination causing accidents like fire. Do not use damaged wire, socket or appliances with loose plug, otherwise accidents like electric shock, short circuit and fire may occur. Make sure power plug closely fits with power socket. Power socket for water heater shall be located in a dry place free of water spray. Do not insert or pull the power plug with wet hands, for accidents like electric shock or injury may happen. For first use after installation, the tank must be full of water before connecting the power. Otherwise, heating element overheat may cause troubles.Children taking shower must be attended by adults. Please do not point the showerhead towards human body when turning on or off the faucet, avoiding to be scalded by a small stream of hot water. Do not install it outdoors. Do not install it as stand-alone. It shall be hung on firm and solid wall. Do not install it in places unable to drain water. Symbol Denotation Do not proceed!Wrong operation may cause fatal injury or death. Do follow the instructions!Wrong operation may cause human injury or house property loss. Installation must be made by installers of or designated by our company after-service department. The water heater shall be wall-mounted. Before installation, make sure water heater rear wires are fit firmly. Determine an installation location. Make four holes 12mm, 65 mm dee pin the wall. Insert and fix expansion hooks and expansion bolts in corresponding wall holes. Lift the water heater. Insert wall rack onto the hooks and bolts. Fit flat washers, rear wires, spring washers and nuts in turn onto the bolts. Tighten the nuts and check them firm. Install accessories such as safety valve, drain ...
Ce manuel est également adapté pour les modèles :Chauffe-eau - Little Sea-ox FCD-JTHC80A-III (E), FCD-JTHC100A-III(E) (1.06 mb)