Inhibited propylene glycol is recommended. Do not use automotive, ethylene glycol or undiluted antifreeze. Severe personal injury, death or substantial property damage can result. 50% solution provides protection to about — 30°F. Local codes may require back-flow preventer or actual disconnect from city water supply. Determine quantity according to system water content. Boiler water content is listed on back cover. Remember to add in expansion tank water content. Follow antifreeze manufactu
To the installer: Leave all instructions with boiler for future reference. Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee. Part No. 550-110-494/0487WP Table of Contents Section VII: Wiring & Fuel Line Piping Section I: Pre-Installation Air Supply for Combustion.......................... 3 Chimney or Vent Requirements ......................3 Standard Minimum Clearances.......................4 Boiler Foundaton...
All mechanical equipment needs occasional attention. The boiler should be inspected, cleaned and if necessary, adjusted once a year. We recommend that your serviceman be called as he has been trained for the job and will have the necessary instruments to check your boiler. This will assure you that the operation of your heating system will remain highly efficient. Your Weil-McLain boiler will give you a lifetime of heating comfort, if you follow the few simple suggestions listed on this card. F
Hd. SlotZP ■ 16 Rollout Thermal Fuse Element W-M 10C257 ■ LISTED PART OR EQUIVALENT CAN BE PURCHASED AT LOCAL SUPPLY HOUSE. * SOLD AS ASSEMBIY ONLY ll8l Base Assembly CGX Series 1 6 12 FIG. NO. DESCRIPTION BOILER SERIES NO. SALES REF. NUMBER 9 Base Rear Spacer Strip For Burners -CGX-3 1 11B433 CGX-4 1 11B434 CGX-5 1 11B435 CGX-6 1 11B436 10 Manifold Assembly CGX-3 1 11B437 CGX-4 1 11B438 CGX-5 1 118439 CGX-6 1 11B440 11 Main Burner Orifice (35 Drill) 1 11B446 12 Base Insu
. . Control Supplement and Gas Control Parts for Natural or Propane gas with optional tankless heater application EGH Read all instructions before installing Installer Leave all instructions with boiler for future reference. Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee. Owner Installation and service should be performed by qualified service technician. Part No. 550-110-639/0703 EG, PEG, EGH GAS-FIRED BOILERS — SERIES
• Seperate burner manual provided with burner. 2. Use pipe joint compound (pipe dope) resistant to corrosive action of fuel oil or liquified petroleum gases. Apply sparingly to male threads of pipe joints. Do not use any kind of pipe tape. 3. Oil piping – use flare-type fittings, not compression type. Do not use compression or soldered fittings. No safe repair can be made. Severe personal injury, death or substantial property damage will result. Propane boilers — see WARNING on page 39 regarding
Indicates presence of hazards that will cause severe personal injury, death or substantial property damage if ignored. Indicates presence of hazards that can cause severe personal injury, death or substantial property damage if ignored. Indicates presence of hazards that will or can cause minor personal injury or property damage if ignored. Indicates special instructions on installation, operation, or maintenance that are important but not related to personal injury hazards. Symbol Definitions T
Do not contact Weil-McLain. This will only slow up the process. What is involved in submitting a claim? Upon completion of repairs, contractor performing work submits: ■ Claim forms: May be submitted on any standard work order form Musi be signed by the homeowner Must be sent within 45 days of the date of service No limit on number of claims allowed ■ Information required: TAW dealer number—TAW contract number- Homeowner name, address, and signature- Ultra boder model number- Boiler CP (
------ SYSTEM PROVE SHUTDOWN /TSTAT /SETBACK ENCLOSED ENERGY MANAGEMENT EQUIPMENT LISTED 99RA CAUTION: RISK OF ELECTRIC SHOCK More than one disconnect switch may be required to de-energize the equipment before servicing. CUS WARNING This Weil McLain control is strictly an operating control; it should never be used as a primary limit or safety control. All equipment must have its own certified limit and safety controls required by local codes. The installer must verify proper operation and correc
By installing two plugged tees as shown in Figure 19, a tank can easily be added if necessary. Obtain Bulletin AE-8403 from your Weil-McLain distributor for tank sizing. HEADER AND SUPPLY RISERS SAME SIZE AS OLD SYSTEM —OR PER ASHRAE RECOMMENDATIONS NOTE: SWING JOINTS NOT SHOWN FIGURE 19 RECOMMENDED PIPING FOR REPLACEMENT STEAM BOILER—ONE-PIPE SYSTEM Section V: Tankless & Storage Heater Hook-up TANKLESS HEATER HOOK-UP Install as shown in Figure 20 (water boiler) or Figure 21 (steam boil