Log:
Téléchargements : 1   Taille : 40 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

FOR STANDING PILOT MODELS WITH ROBERTSHAW GAS VALVE, 2 STAGE OPERATION. (Models 90, 135 & 180) 1. STOP! Read the safety information. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the appliance. 4. Push in and move gas control lever counterclockwise to "OFF" position. GAS CONTROL LEVER SHOWN IN "OFF" POSITION GAS INLET Fig. #8934.0 NOTE: Lever cannot be moved from "ON" to "OFF" unless lever is pushed in slightly. Do not force. 5. Wait five (5) minutes to clear out

Téléchargements : 0   Taille : 40 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

LIGHTING INSTRUCTIONS FOR STANDING PILOT MODELS. Some safety information you need to read and under stand before operating the boiler. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This boiler has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING Smell all around the boiler area for gas. Be sure to smell next to the floor beca

Téléchargements : 1   Taille : 40 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

#8934.0 ROBERTSHAW (All Models) 8. Turn on all electric power to the boiler. 9. Set thermostat to desired setting. 10. If the boiler will not operate, follow the instruction "To Turn Off Gas To Boiler" and call your service technician or gas supplier. TO TURN OFF GAS TO BOILER 1. Set the thermostat at the lowest setting. 2. Turn off all the electric power to the boiler if service is to be performed. 3. For Honeywell Valve: Turn gas control knob clockwise to "Off". Make sure knob rest against sto

Téléchargements : 0   Taille : 40 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

3. For Honeywell Valve: Turn gas control knob clockwise to "Off". Make sure knob rest against stop. For Robertshaw Valve: Push in and move gas control lever to "Off" position. HONEYWELL PILOT CAUTION: Should overheating occur or the gas supply fails to shut off, DO NOT turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance. Failure to observe this precaution may aggravate the overheated condition resulting in possible da

Téléchargements : 2   Taille : 40 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

Inspect the vent terminal outside the building. Make sure it is not damaged to cause blockage or restriction of the flue gas. Observe for any indication of soot. The presence of soot accumulation in the vent terminal would indicate an abnormal operating condition. This should be investigated and corrected by a qualified service agency. SOOT CORROSION DISENGAGED Fig. #8204.0 3. Circulator (Water Pump) Inspection. The circulator is permanently lubricated and thus, will not require any lubrication.

Téléchargements : 4   Taille : 40 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

A. This boiler does not have a pilot. It is equipped with a hot surface ignition device which automatically lights the burners. Do not try to light the burners by hand. B. BEFORE OPERATING smell all around the boiler area for gas. Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS * Do not try to light any appliance. * Do not touch any electric switch; * Do not use any phone in your building. * Immediately call you

Téléchargements : 0   Taille : 97 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

F. Boiler Control 1. The following safety controls shall be provided: a. High limit control b. Flow switch c. PSIG ASME pressure relief valve, piped by the installer to an approved drain d. Temperature and pressure gauge 2. The boiler(s) shall be equipped with an energy-saving pump control relay (Economaster), mounted and wired, which automatically shuts off the boiler pump at a set period after boiler shut-down (adjustable for two settings of five or ten minutes) to avoid standby losses associa

Téléchargements : 0   Taille : 113 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

Related Sections Specifier Note: Use as needed 1. Building Services Piping – Division 23 21 00 2. Breeching, Chimneys, and Stacks (Venting) – Division 23 51 00 3. HVAC Instrumentation and Controls – Division 23 09 00 4. Electrical – Division 23 09 33 1.2 REFERENCES A. ANSI Z21.13/CSA 4.9 B. ASME, BPV Section IV C. 2006 UMC, Section 1107.6 D. ANSI/ASHRAE 15-1994, Section 8.13.6 E. National Fuel Gas Code, ANSI Z223.1/NFPA 54 F. I=B=R G. National Electrical Code. ANSI/NFPA 70 H. ASME CSD-1, 2009 (w

Téléchargements : 0   Taille : 113 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

G. Firing Mode 1. For models 992BE, provide three-stage firing control of the gas input to the boiler. 2. For models 1262BE-2342BE, provide four-stage firing control of the gas input to the boiler. H. Boiler Diagnostics 1. Provide external LED panel displaying the following boiler status/faults: a. Power on – Blue b. Call for heat – Amber c. Flow – Green d. Stages 1-4 – Green e. Fans 1-3 proven – Green f. Ignition fault – Red g. Safety fault – Red 2. Provide internal circuit board with fault his

Téléchargements : 0   Taille : 114 kb   Fabricant : Raypak  
Catégorie : Chauffe-eau
@name

Air, Cond. Drain) ■ Combustion Air Filter ■ Design Certified ANSI Z21.10.3/CSA 4.3 Venting ■ Vent Termination □ Outdoor or Indoor, Vertical -Option D-11 □ Indoor, Horizontal - Option D-15 ■ Extractor - Optional □ By others □ Not required Multi-Boiler Digital Temp Controllers □ B-36 TempTracker Mod+, 2-4 Water Heaters □ B-37 TempTracker Mod+, 5-10 Water Heaters □ B-38 TempTracker Mod+, 11-16 Water Heaters Options □ F-10 □ I-5 □ S-1 □ S-2 □ Z-12 Low Water Cut-Off, Remote Pro





catégories