Log:
Téléchargements : 6   Taille : 239 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

3. This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. 4. The Benchmark Checklist may be required in the event of any warranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information Pack. © Baxi Heating UK Ltd 2009 6.0 Notes © Baxi Heating UK Ltd 2009 6.0 Notes 10 © Baxi Heat

Téléchargements : 7   Taille : 316 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988. Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should b

Téléchargements : 1   Taille : 619 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

Baxi Combi Instant 105e Gas Fired Wall Mounted Combination Boiler User’s Operating Instructions Natural Gas Baxi Combi Instant 105e G.C.No 47 075 09 Baxi UK Limited is one of the leading manufacturers of domestic heating products in the UK. Our first priority is to give a high quality service to our customers. Quality is designed into every Baxi product -products which fulfil the demands and needs of customers, offering choice, efficiency and reliability. To keep ahead of changing trends, we hav

Téléchargements : 5   Taille : 691 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

Check electricity to the boiler is switched on. Is the Central Heating System YES NO Is the ( ) indicator neon on ? section, between 1 and 2.5 bar ? Pressure needle in the GREEN NO 30° 40° 50° 60° 70° 80° bar01234 Flame Failure Neon YES If the reading falls below 1 bar repressurise the system as Turn the ON/OFF/Reset described in section 4.1. Selector Switch to Reset. Reset If boiler does not Reset © Baxi Heating UK Ltd 2009 2.0 Troubleshooting Is the Timer ON and calling for Is the Room Thermos

Téléchargements : 3   Taille : 717 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

Please leave these instructions with the user for safe keeping. Commissioning, Maintenance & Servicing Guide Potterton Solar -Solar Thermal Domestic Hot Water System © Baxi Heating UK Ltd 2007. IndexIndex 2 Index 3 Commissioning of system General information Flushing and filling the system 5 Commissioning of hydraulic station Checking/setting pressure Checking/adjusting flow rate Installation of thermal insulation 7 Commissioning of solar controller Overview of display Button function Operating

Téléchargements : 7   Taille : 814 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

Read the instructions fully before installing or using the appliance. 2. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. 3. Definition of competence: A person who works for a CORGI registered company and holding current certificates in the relevant ACS modules, is deemed competent. 4. IN IE (Eire), this must be carried out by a competent person as stated in I.S. 813 “Domestic Gas Installations”. All CORGI registered installers c

Téléchargements : 10   Taille : 816 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

© Baxi Heating UK Ltd 2008 Contents Natural Gas Potterton Promax Combi 24 HE Plus A G.C.No 47 393 21 Potterton Promax Combi 28 HE Plus A G.C.No 47 393 22 Potterton Promax Combi 33 HE Plus A G.C.No 47 393 23 .. This product has an energy rating (A) on a scale of A to G. For more information see This is a certification mark. Section Page 1.0 Quick Reference Guide 3 2.0 Troubleshooting 4 3.0 Repressurising System 6 4.0 Clearances 7 5.0 Care of the Boiler 8 6.0 Legislation 9 7.0 Notes 10 “Potterton”

Téléchargements : 25   Taille : 870 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

3.5 Safety Thermostat 1. Your Baxi Combi HE is fitted with an additional safety devices, which shut down the boiler in the event of the system, boiler or flue overheating. The safety thermostat neon ( ) will light in this instance (Fig. 1). 3.6 Flame Failure 1. The red flame failure neon ( of the burner failing to light, when incomplete lighting of the ) will illuminate in the event burner occurs or blockage of the condensate drain (Fig. 1). To Reset the Safety Thermostat or Flame Failure 1. To

Téléchargements : 8   Taille : 970 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

4. This loop MUST be connected to the taps. Remove the blanking cap and set aside. 5. Connect the loop to the taps with the wing nuts. These should be hand tightened. 6. Carefully open the handles on both taps and check the boiler pressure gauge. Once the needle on the gauge is above the 0.5 mark both taps can be closed. 7. Undo the two wing nuts, remove the loop and refit the blanking cap. Put the loop in a safe place for future use. © Baxi Heating UK Ltd 2007 4.0 Clearances 5mm Min 450mm 5mm M

Téléchargements : 0   Taille : 970 kb   Fabricant : Baxi Potterton  
Catégorie : Chauffe-eau
@name

If you move house, please hand them over to the next occupier. © Baxi Heating UK Ltd 2007 Contents Natural Gas Potterton Gold Combi 24 HE G.C.No 47 590 05 Potterton Gold Combi 28 HE G.C.No 47 590 06 Potterton Gold Combi 33 HE G.C.No 47 590 19 Section Page 1.0 Quick Reference Guide 3 2.0 Troubleshooting 4 3.0 Repressurising System 6 4.0 Clearances 7 5.0 Care of the Boiler 8 6.0 Legislation 9 7.0 Setting the Timer 10 8.0 Emergency 11 9.0 Warranty & Service 12 © Baxi Heating UK Ltd 2007 All rights