• WARNING: Water in excess of 100 degrees Fahrenheit may be hazardous to your health. • WARNING: To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. • A green colored terminal marked “Earth Ground” is located inside the wiring compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment. • One bonding lug for US models (two for Canadian models) is provided on the external surface. To reduce the risk of electric shock, connect the local common bonding grid in the area of the swimming pool, spa, or hot tub to these terminals with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada. • All field installed metal components such as rails, ladders, drains, or other similar hardware within 3 meters of the pool, spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than 8 AWG US / 6 AWG Canada. • SAVE THESE INSTRUCTIONS Table of Contents Introduction 1. Preparing Pool/Spa Water 2. Mounting Equipment 3. Plumbing 4. Electrical Wiring 5. Configuration 6. System Startup and Checkout 7. Warranty Before You Begin................................................................... 1 Plumbing Requirements....................................................... 2 Electrical Requirements....................................................... 2 Installation Steps.................................................................... 2 General Water Chemistry..................................................... 3 Salt.......................................................................................... 4 Aqua Logic Control Center................................................... 6 Temperature Sensors........................................................... 6 Optional Wired Remote Display/Keypad........................... 6 Optional Wireless Remote Display/Keypad....................... 7 Optional Base Receiver........................................................ 7 Valve Actuators...................................................................... 7 General Equipment............................................................... 8 Turbo Cell............................................................................... 9 Flow Switch............................................................................ 9 Main Service.......................................................................... 10 Grounding and Bonding........................................................ 11 Circuit Breaker Installation and Wiring......................... ...... 11 General Purpose Outlet........................................................ 11 Aqua Logic Control Power................................................... 11 High Voltage Pool Equipment.............................................. 12 Low Voltage Wiring............................................................... 13 Configuration Menu.............................................................. 19 Before Startup........................................................................ 26 Heater Checkout................................................................... 26 Service Mode........................................................................ 27 Aqua Logic Limited Warranty.............................................. 28 Introduction Before You Begin Before installing the Aqua Logic System -Determine that you have everything necessary to complete the installation-Find a suitable mounting location for both the control center and remote keypad-Plan and determine where components will be plumbed-Plan wire runs and wiring connections What’s Included Before attempting to install the Aqua Logic system, check that the following components have been included in the package: Aqua Logic Electronics Unit (2) Temperature sensors with 12 ft. (4m) cable, hose clamp TurboCell kit (1) Turbo Cell with 12ft. (4m) cable with unions (1) Flow switch with 12ft. (4m) cable What’s NOT Included Some of the additional items that you may need to complete an installation include: Circuit breakers None are included with control—see page 11 and inside of door for suitable breakers Wire 4-conductor cable (electronics unit to remote display/keypad) Wire/conduit for 100A service from main panel to Aqua Logic Wire/conduit for filter pump and other high voltage loads Wire for bonding Miscellaneous Utility electrical outlet and weatherproof cover (for mounting on side of Aqua Logic) Mounting hardware (screws, etc.) for mounting Aqua Logic and remote display/keypadValves (use standard Jandy, Pentair/Compool, or Hayward valves) Valve, actuator, and solar sensor for solar control option. Additional cable for the solar sensor may alsobe required Accessory Products - Order Sep...