Log:
Évaluations - 3, GPA: 4 ( )

Instructions Blueair, Modèle 120-60-1

Fabricant : Blueair
Taille : 70.33 kb
Nom Fichier : 31kax-11si.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Recognize safety information. This is the safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. INTRODUCTION This instruction covers the installation of power supply kit Part No. 322044-701 in an electronic air cleaner with a 120v-60Hz-1 phase power supply. DESCRIPTION AND USAGE The kit is designed to replace both current and previous design power supplies for duct-mounted models only. See Step 2 for models 31MB and 907A; see Step 3 for models 31MM, 31MP, 901A and B also 907B and C; see Step 4 for models 31SX, 120v 31KAX, 901E and G, 120v 901KAX; see Step 5 for 240v models 31SX, 31KAX, 901E, 901KAX, and 901G. The kit contains the following items: Power supply 1 Busbar assembly (2-3/16 in., 4-13/16 in., and 8-1/2 in.) 1 each Wirenut 4 Phillips-head sheet-metal screw 4 6-32 machine screw 2 Hex nut 1 Wire clip 1 Angle bracket 1 Installation Instructions 1 INSTALLATION Step 1—Remove Power Supply 1. Turn off main electrical supply to air cleaner and air handler. 2. Remove power door from air cleaner. Remove inside of door to expose the power supply. 3. Disconnect existing wires from existing power supply. 4. Remove existing power supply from power door. Use care when attaching wires or bus bar to the new power supply to avoid damaging terminals and/or printed-circuit board. Step 2—Install New Power Supply in Model 31MB or 907A 1. Cut terminal ends off wires disconnected from failed power supply and strip 1/2 in. insulation from wires. 2. Using 4 sheet-metal screws provided in kit, install new power supply. 3. Choose proper length bus bar (2-3/16 in.) and assemble angle bracket to bus bar. (See Fig. 1.) 4. Using machine screw and nut, attach existing surge resistor to angle bracket. (See Fig. 1.) 5. Attach bus bar to high-voltage terminal of power supply. 6. Using wire nuts provided in kit, splice wires. Violet wire can attach to either red wire. (See Fig. 1.) 7. Route wires so they will not contact high-voltage circuit and install wire clip. 8. Reinstall power door in air cleaner. 9. Turn on main electrical supply to the air cleaner and air handler. 10. Check air cleaner for proper operation before leaving job. ® Step 3—Install New Power Supply in Models 31MM, 31MP, 901A and B, also 907B and C 1. Using 4 sheet-metal screws provided in kit, install new power supply. 2. Cut terminal ends off wires disconnected from failed power supply and strip 1/2 in. of insulation from wire. Splice wires to new power supply wires with wire nuts provided in kit. (See Fig. 1.) 3. Remove existing surge resistor, if applicable, and discard. Surge resistor...

Ce manuel est également adapté pour les modèles :
Air - 120-60-1 (70.33 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories