Facilité d'utilisation


(See Figure 15) 7. Remove tag and alcohol from lamp. Wipe off lamp being sure not to ouch lamp with bare hands. The oils from your hands will reduce lamp output. 8. Insert lamp through hole until lamp cannot be inserted any further. (See Figure 16) 9. Swing swivel bracket over end of lamp. Hand-tighten the wing nut on stud. (See Figure 17) Be careful not to over tighten the wing nut. The porcelain at the lamp base may crack when over tightened. 10. Plug ballast plug into end of lamp. (See Figure 18) Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 5 11. Replace cover on unit. Tighten side screws. (See Figures 19 & 20) 12. Plug the power cord into a standard electrical outlet. NOTE: Seal the joints and seams of the plenum near the mounting location to reduce any direct viewing of light. (See Figure 1) 13. Flip switch on box to the ON position. (Light on switch should be on, indicating power.) 14. Look through view port in the box cover to be sure lamp is working. You should see a blue glow. (The view port is covered with a plastic lens that blocks the UV-C rays.) 15. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 1-252-522-3031 for further assistance. BULB MOUNTING BRACKET SELECTION AND INSTALLATION The UV-Aire units come with an angled mounting bracket and flat mounting bracket to position the bulb either straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to the configurations chart below when making your selection. Figure 19 Figure 20 UV-Aire Configurations Good Best Patent Pending 45. Installation Single Lamp Angle Bracket (16” Duct) Standard 90. Installation Flat Bracket (16” Duct) WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 6 page 7 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. LAMP REPLACEMENT PROCEDURE VERY IMPORTANT: Turn switch on unit to OFF position and unplug unit from outlet. Loosen the cover screw on the s 1. ide of the unit and open cover. 2. Unplug ballast plug from end of lamp. 3. Loosen the wing nut on swivel bracket and rotate the bracket clockwise. 4. Slide lamp out carefully. NOTE: When replacing the lamp, always wipe off lamp before installing. 5. Replace lamp following the appropriate procedure based on bracket selection in the installation section. 6. Attach the ballast plug onto the end of the lamp. WARNING: UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule, these types of lamps may be disposed of into household waste. 7. After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to the housing and dated with the date of installation. LAMP OFFSET DIMENSIONS Unit Min. Duct Size (inches) A B UV-12 9 x 12 81.2 61.2 UV-18 14 x 18 131.2 105.16 Chart A Chart B ANGLED LAMP MOUNTING BRACKET SPECIFICATIONS Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire unit on the duct. MAINTENANCE 1. Inspect and clean lamp at least every 6 months. 2. Replace your UV-Aire Air Purifying System lamp once a year to maintain the lamp’s maximum output intensity. The lamp should operate continuously for maximum lamp life and light effectiveness. TROUBLESHOOTING GUIDE 1. If unit does not light up, replace bulb. 2. If unit still does not light up after replacing bulb, replace ballast. REPLACEMENT PARTS LIST MODEL LAMP (Field Controls Part Number) BALLAST (Field Controls Part Number) UV-12 46365401 46365508 UV-18 46365402 46365509 For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at: • Phone: 252-522-3031 • Fax: 252-522-0214 • Email: sales@fieldcontrols.com LIMITED WARRANTY Field Controls, LLC (“Company”) warrants that its products shall be free from defects in material and workmanship under normal use for the limited period indicated, from the date of manufacture, subject to the provisions 1-8 below. Eighteen (18) months All Field Controls Products (except for those listed below as 5 years or 90 days). Five (5) years Field Controls Direct Vent Systems (FDVS...

Ce manuel est également adapté pour les modèles :
Air - UV-12 (1.28 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories