GENERAL INFORMATION There are different size units available, depending on the square footage of your home. See chart below for determining your home’s needs. MODEL MINIMUM DUCT WIDTH VOLTS AMPS Hz WATTS MAx AIR TEMP .F LAMP INTENSITY AT 1 METER RECOMMENDED MAx. Sq. FEET UV-12C 9" 120 0.5 60 30 190. 37 .W/cm2 1500 UV-18C 14" 120 0.5 60 30 190. 73 .W/cm2 2000 UV-28C 22" 120 1.1 60 60 150. 105 .W/cm2 3000 UV-28 22" 120 1.1 60 60 150. 105 .W/cm2 3000 UV-12HP 9" 240 0.5 60 30 190. 37 .W/cm2 1500 UV-18HP 14" 240 0.5 60 30 190. 73 .W/cm2 2000 UV-28HP 22" 240 1.1 60 60 150. 105 .W/cm2 3000 UV-12HPC 9" 240 0.5 60 60 190. 37 .W/cm2 1500 UV-18HPC 14" 240 0.5 60 30 190. 73 .W/cm2 2000 UV-28HPC 22" 240 1.1 60 30 150. 105 .W/cm2 3000 The UV-12C,18C, 28C,12HPC,18HPC, and 28HPC units are equipped with a circuit board to monitor the operation of the UV lamp; it indicates the operation of the lamp through an LED indicator light mounted on the cover of the unit. The circuit board indicates good operation of the lamp by a continuous GREEN color on the LED light. After 8,320 hours of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous YELLOW color on the LED light and the internal alarm will beep every 15 minutes. After 9,000 hours of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous RED color on the LED light and the internal alarm will beep every 5 minutes. The board also checks if the UV lamp is burned out. If the lamp is burned out, the circuit board will indicate this by a continuous RED color on the LED and the internal alarm will beep every 5 minutes. WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have units unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UV-C light from any source. WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier. WARNING: Designed for a closed duct system. Do not mount near a return air opening. WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). For use on gas fired, oil fired, electric and split system heat pump forced air systems*. This product is NOT designed to be mounted outside on gas fired or heat pump packaged units**. * Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units. **Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building. WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 2 INSTALLATION 1. Locate a suitable location for the unit downstream ...
Ce manuel est également adapté pour les modèles :Air - UV-12HPC (1.03 mb)
Air - UV-28HPC (1.03 mb)
Air - UV-28HP (1.03 mb)
Air - UV-28C (1.03 mb)