Log:
Évaluations - 4, GPA: 4 ( )

Instructions Amcor, Modèle AM-45

Fabricant : Amcor
Taille : 390.62 kb
Nom Fichier : da073803-cd9a-4a8f-bee0-725aec261900.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


b. The unit will operate for the selected Time interval (1 hr, 2 hrs, 4 hrs or 8 hrs) and then turn off the unit. After the appropriate time period has passed the green light will move to the next lower position in order to show the remaining time. 6. The Remote Control turns the unit on and off (see point 1 above). For long operating distance the Remote Control should be pointed at the area just below the POWER (A) button. D: UV C: IONIZER B: TIMER A: POWER 5 Cleaning Cleaning Always disconnect the the electrical servicing the unit! Note that the servicing intervals mentioned in this section based on air purifier use of per day in a normal household environment. If your use of the air purifier differs from that described above, then you can adjust the servicing intervals accordingly. 1. Clean the outside of the AM-45 and the area around the air purifier with a soft damp cloth once every 2 weeks. If you are not using the Ionizer, then this interval can be increased to once a month. 2. Access to the AM-45 filters and serviceable components is by removing the rear cover. To remove the rear cover, push the button above the rear cover while pulling back on the rear cover. The rear cover will pivot away from the main unit and then it can be lifted up and away. The rear cover is reinstalled by fitting the projection at the bottom of the rear cover into the slot at the back of the main unit and then closing the top of the cover until it snaps into place. 3. The Pre-Filter is removed from the rear cover, by sliding it out the upper edge of the rear cover. The Pre-Filter is reinstalled by sliding it back in the slot from where it was removed. The Pre-Filter should be washed in warm soapy water or with a water spray once a month. Make sure that the Pre-Filter is completely dry before reinstalling it. 4. Inside the rear cover facing the front of the unit are 6 ionizing needles that work together with the Aluminum Mesh Filter to make the Electrostatic Filter. The needles are inside protective cylinders and the needles should be cleaned with a brush once a month. 5. The Aluminum Mesh Filter is visible looking at the open back side of the main unit. The Aluminum Mesh Filter frame holds both the Aluminum Mesh Filter and the Granulated Active Carbon Filter. Remove the Aluminum Mesh Filter frame by lifting the tab above the filter and then by pulling backwards towards the user on the upper part of the filter. The Granulated Active Carbon Filter is removed from the Aluminum Mesh Filter frame, by sliding it out the upper edge of the Aluminum Mesh Filter frame. Note that this needs to be done before washing the Aluminum Mesh Filter. The Granulated Active Carbon Filter is reinstalled by sliding it back in the slot from where it was removed. The Aluminum Mesh Filter frame is reinstalled by fitting the bottom of the filter frame into its place at the back of the main unit and then closing the top of the filter frame until it snaps into place. a. The Aluminum Mesh Filter should be washed in warm soapy water once a month. Make sure that the Aluminum Mesh Filter is completely dry before sliding the Granulated Active Carbon Filter into its place in the Aluminum Mesh Filter frame and reinstalling the filter pair into its place at the back of the main unit. b. The Granulated Active Carbon Filter should be replaced once a year. If the Granulated Active Carbon Filter is dusty, it can be cleaned gently with a vacuum cleaner. c. While the Aluminum Mesh Filter frame is out of the unit, the interior of the unit should be wiped with a soft dry cloth. continued on page 7 6 Cleaning Cleaning fig. 1 fig. 2 6. The UV lamp (fig. 1) is visible looking at the open back side of the main unit after the Aluminum Mesh Filter has been removed). The UV lamp is removed by rotating it 1/4 turn and then sliding it out of the top and bottom lamp sockets. The UV lamp is reinstalled by sliding it into the top and bottom lamp sockets and rotating it 1/4 turn. The UV lamp should be replaced once a year. 7. The PCO filter (fig. 2) is accessible, when the Aluminum Mesh Filter and UV lamp are out of the unit. The PCO filter is removed by lifting the tab above the filter and then by pulling backwards towards the user on the fabric strip at the upper part of the filter. The PCO filter is reinstalled by fitting the bottom of the filter into its place at the back of the main unit and then closing the top of the filter until it snaps into place. The PCO filter should be washed in warm soapy water when replacing the UV lamp. Make sure that the PCO filter is completely dry before reinstalling it. 8. The Carbon Cord which is the negative ion emitting element is accessible at the front grill of the unit. The Carbon Cord should be wiped lightly with a soft piece of paper tissue once every 6 months. The paper tissue should be thrown away after using it. 7 Specifications Specifications Model Number AM-45 Power consumption 25W Power supply 120V / 60Hz Fan speeds 3 Timer 1-8 hour...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories