See page 7 for details. 5” Filter - collects dust, dirt and other particles. 5" FILTER Figure 2 3 PREINSTALLATION LOCATING THE AIR FILTER Your air filter must be mounted in the return air duct of a central forced-air system, on the air entering side of your furnace. (See Figure 3 for example.) Select a location that meets the following: 1. The face of the filter will be at a right angle to the air stream. 2. Allow 25” of clearance in front of the air filter compartment door to permit removal of filters. See figure 4 for complete compartment dimensions. 3. The air filter is not to be placed in the discharge of either the heating or cooling unit. 4. IMPORTANT: If atomizing spray type humidifier is used, it must be installed downstream from the air filter. If furnace opening cannot be enlarged to required size, a transition sheet metal section must be used. Transition must be planned for each job. Reduction should not be more than 4 inches per linear foot, approximately 20 angular degrees (Figure 3). AIR FLOW NOT TO EXCEED 20 FURNACE OPENING FURNACE AIR CLEANER DUCTWORK AIR FLOW THIS CABINET CAN ACCEPT ELECTRONIC AIR CLEANER OPTION (SEE PAGE 7) AIR CLEANER OPENING TRANSITION SECTION (IF NEEDED) Figure 3 DCBEA67/8 Model No. A B C D E ACB/ACM1000 20-1/4 12-5/8 13-9/16 16-7/16 19-1/16 ACB/ACM1400 26-1/4 23-5/8 13-9/16 16-7/16 19-1/16 ACB/ACM1600 20-1/4 12-5/8 17-3/4 20-5/8 23-3/8 ACB/ACM2000 26-1/4 23-5/8 17-3/4 20-5/8 23-3/8 Figure 4 4 TYPICAL MOUNTING POSITIONS AIR FLOW Figure 5 Figure 6 BASEMENT FURNACE (LOWBOY) (Figure 5) Filter is mounted horizontally in return plenum, just above furnace. AIR FLOW COUNTERFLOW FURNACE (Figure 6) Filter is mounted horizontally in return duct or plenum, just above furnace. AIR FLOW Figure 7 HIGHBOY FURNACE (Figure 7) Side installation. Filter is mounted vertically, where return air enters side inlet of furnace. HIGHBOY FURNACE (Figure 8) Installation beneath furnace. Filter mounts horizontally, where return air enters from below. Raise furnace and install beneath base. AIR FLOW Figure 10 HORIZONTAL FURNACE (Figure 10) Filter is mounted vertically in the return duct near furnace. LESS THAN 7 INCHES FIGURE 9 OFFSET AT LEAST 9 INCHES OFFSET INSTALLATION (Figure 9) Typical use of duct offset to match air filter opening. If duct connection to furnace allows less than nine inches for mounting the air filter, shorten the lateral trunk, or attach an offset fitting to the elbow. 5 Optional method (Bend tabs outward at 90° angle) Optional method (Bend tabs outward at 90° angle) N REMOVE OLD FILTER AND DISCARD (Figure 11) NOTE: This filter may be mounted in the furnace compartment. CLEAN BLOWER COMPARTMENT NOTE: The air filter cannot remove dirt from blower and ducts. INSTALLATION The following is a typical installation of the air filter on a “Highboy” furnace (Figure 7). 1. Place the air filter compartment on the floor. Stand it upright with the door facing you (Figure 2). If a horizontal installation is being planned, lay the...

Ce manuel est également adapté pour les modèles :
Air - ACM1400 (341.57 kb)
Air - ACM1600 (341.57 kb)
Air - ACM2000 (341.57 kb)
Air - ACB1400 (341.57 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories