Log:
Évaluations - 3, GPA: 3.7 ( )

Instructions Hunter Fan, Modèle 30401

Fabricant : Hunter Fan
Taille : 1.06 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Fig. 11 Clock Display Fig. 12 Pre-Filter Display Fig. 13 Filter Display DISPLAY 41451-01_Rev 8-6-04.pmd 8 8/5/04, 5:05 PM 9 41451-01 Operation Manual and Auto Operating Modes Your Hunter Air Purifier has two distinct operating modes – Manual and Auto. The Manual Mode allows you to override the control programs that have been set and to hold the settings until you adjust them. In Manual Mode, the automatic programs are not active. You select whether the unit is on or off and choose the blower speed. In Auto Mode, your air purifier is capable of running 4 separate programs for the weekdays and an additional 4 programs for the weekend. You can choose to have the same programs for every day or you can have different programs for the weekdays and the weekend. The air purifier is pre-programmed for all 7 days of the week as shown below. Refer to User Programming on pg. 14 for instructions on changing the programs. Table 1: Pre-set Programming Provided for Each Air Purifier To switch between Manual and Auto Modes: 1. To change operating modes, press the AUTO key. The current operating mode will appear on the display (either AUTO or MANUAL). 2. When changed to Auto Mode, the unit will automatically adjust its controls to the appropriate program for the day and time. When Manual Mode is active, the unit will maintain current settings until you change them. Program Setpoint Time Blower Speed 1 8:00 am 2 (Medium) 2 3:00 pm 3 (High) 3 5:00 pm 2 (Medium) 4 10:00 pm 1 (Low) AUTO Fig. 14 Auto Mode Fig. 15 Manual Mode 41451-01_Rev 8-6-04.pmd 9 8/5/04, 5:05 PM 41451-01 10 Operation Override of Auto Mode You can use two different methods to override Auto Mode. If you choose temporary override, the air purifier will run at the temporary setting until the next scheduled program change. Permanent override will remain in effect until you return the unit to auto mode. Fig. 16 Fig. 17 AUTO AUTO AUTO Temporary Override • To temporarily override the settings: 1. While the Auto Mode is active, use the UP/DOWN keys to adjust the blower speed. To temporarily turn the blower off, turn the blower speed to 0. This will allow the program to automatically continue at the next scheduled program change. 2. The air purifier will automatically adjust to the new setting. The current program number will flash to signify the temporary override. • To end the temporary override: 1. The temporary override will automatically end at the next scheduled program change. 2. To immediately end the temporary override and return to the program, press the AUTO key twice. The air purifier will return to Auto Mode and the scheduled program. Permanent Override • To begin permanent override: 1. Press the AUTO key to enter manual mode. On the display, you will see the word MANUAL illuminated. This indicates that the programs are no longer active and the unit is in Manual Mode. 2. Use UP/DOWN keys to adjust the blower speed. • To end the permanent override: 1. Press the AUTO key. The display will now show the word AUTO. 2. The unit will automatically adjust its controls to the appropriate program for the day and time. 41451-01_Rev 8-6-04.pmd 10 8/5/04, 5:05 PM Operation Filter Run-Time Counters The pre-filter and filter are critical to the proper operation of the air purifier. To help you know when to change the filters, your Hunter Air Purifier has Filter Run-Time Counters that will monitor the number of hours your filters have been in use. Although the exact life of the filters depends on the environment, the table below gives typical usage times of the filters. Table 2: Typical Usage Times of the Filters Filter Type Typical Usage Activated Carbon Pre-Filter 2000 hours HEPA Filter 8000 hours To check the run-hours for each filter: 1. Press the DISPLAY key to toggle among the 3 display modes – Clock, Pre-Filter, and Filter. The Filter or Pre-Filter indicator will illuminate when the run hours for that filter are displayed. 2. The display shows the number of run hours since the counter was reset. Although the maximum display value is 9,999 hours, the counters can go indefinitely. To indicate that the counter is over 9,999 hours, the display will flash. For example, a run time of 12,000 hours is represented by a flashing 2,000 hours. The values of the Pre-Filter and Filter Counters are stored in the air purifier’s memory. The unit may be unplugged and moved without losing the pre-filter and filter counter values. To properly track filter usage, the Pre-Filter and Filter Counters should be reset each time the filters are changed. Refer to Changing the Pre-Filter (pg. 18) or Changing the Filter (pg. 19) for instructions on how to reset the counters. Electrical Cord Storage (Selected Models Only) For your convenience, some models have cord wrap posts for easy storage of the electrical cord. The cord wrap posts are located on the back of the air purifier in the bottom corners. When received, the cord wrap posts will be in the collapsed position. To extend the cord wrap p...

Ce manuel est également adapté pour les modèles :
Air - 30130 (1.06 mb)
Air - 30400 (1.06 mb)
Air - 30170 (1.06 mb)
Air - 30175 (1.06 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories