Voltages can exceed 190 VAC (120v motors). Do not wire directly to blower motor. Wiring to blower motor will damage power supply and void warranty. Hz. NOTE: The Infinityt Air Purifier should only be powered when airflow is present. The furnace control EAC spade connections provide power only when the furnace blower is operating. If EAC connections are not available, an alternative airflow sensing mechanism must be used to ensure the Infinityt Air Purifier is only powered when airflow is present. Contact a local Carrier distributor for information on approved alternatives. GAPA CAUTION! UNIT COMPONENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Black Lead - -- Connect to HOT (L1) or EAC- -- 1 when provided. White Lead - -- Connect to Neutral (L2) or EAC- -- 2 when provided. Green/Ground Lead - -- Connect to Appliance Ground (Chassis) 5 6 Sample Furnace Circuit Board Power Cord to EAC Terminals Alternate Power Cord Pass-Thru Hole Use cable connector to secure power cord to cabinet Power Supply Connector Power Supply Use wire ties to secure power cord to power supply enclosure LHT OFF DLY ON OFF W2 BLW EAC-1 TERMINAL Y1 DHUM G COM 24V WW1 Y/Y2 R TEST/TWIN HUM 1 2 3 PLT ACRDJ 0.5-AMP024 VAC FUSE 3-AMP SEC-1 SEC-2 PL1 NEUTRAL-L2 1 EAC-2 BHI/LOR BHT/CLR PL3 1 BLWR COOL SPARE-1 SPARE-2 1-AMP@115 VAC EAC-1 PR-1 IDR HSIR IDM IHI/LOR PL2 1 HSI HI LO STATUSCODELED EAC-2 TERMINAL HI HEAT LO HEAT L1 Use terminals to connect the power cord wires to the furnace EAC-1 & 2, & ground terminals Power Supply Connector Power Cord A06030 Fig. 7 -- Infinityt Air Purifier Electrical Connections START--UP AND OPERATION Step 1—Checking Air Purifier Operation ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. ! WARNING a. Attach the Infinityt Air Purifier door to the cabinet. A magnet in the door (see Fig. 9) is used to activate a safety switch in the power supply when the door is installed. The power supply will not energize the air purifier unless the safety switch is activated. b. Turn the HVAC system power on and adjust the thermostat or Infinityt System Control to activate the system fan. c. Turn the Infinityt Air Purifier power switch to on position. d. The power indicator light above the Air Purifier power switch should illuminiate (see Fig. 8). e. Check to ensure the light goes off when the Infinityt Air Purifier power switch is set to off, when the blower goes off, or when the HVAC system power is turned off. Step 2—Infinity Control a. When the Infinityt Air Purifier is used with an Infinity Control, the Infinity Control can be configured to remind the homeowner when it is time to change the Infinityt Air Purifier cartridge. This maintenance reminder can be based on either the TrueSenset dirty filter algorithm or time. The installer should use their discretion to select the most appropriate option based on the initial system static pressure. Step 3—Maximizing Performance a. Maximum air purification performance is obtained when the furnace blower is set for continuous operation on the thermostat or Infinity Control. Power Indicator A06052 Fig. 8 -- Power Indicator MAINTENANCE The Infinityt Air Purifier is designed to require no cleaning. Maintenance is limited to the replacement of the air purification cartridge. Frequency of air purifier cartridge replacement may vary depending on ductwork design and local environmental conditions. To replace the air purifier cartridge, complete the following steps: Step 1—Turn the heating and cooling system off. ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. ! WARNING GAPA Step 2—Turn the Infinityt Air Purifier switch to the off position. Step 3—Remove the Infinityt Air Purifier door. Step 4—Slide out the old air purifier cartridge and discard. Step 5—Install the new air purifier cartridge. NOTE: Make sure that the arrows on the air purifier cartridge point toward the furnace. This should be in the same direction as airflow. Step 6—Replace the Infinityt Air Purifier door. Step 7—Turn the Infinityt Air Purifier switch to the on position. Step 8—Turn on the heating and cooling system. Door Switch Magnet A06053 Fig. 9 - --Door Switch Magnet TROUBLESHOOTING ! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. The following procedures will expose electrical components. Disconnect power between checks and proceed carefully. The Infinityt Air Purifier is equipped with a power indicator light located on the door (see Fig. 8). This power indicator light will illuminate when the Infinityt Air Purifier door is installed, the power switch is in the on...
Ce manuel est également adapté pour les modèles :Air - INFINITY 1625 (1.87 mb)
Air - INFINITY 1625 (1.87 mb)
Air - INFINITY 2025 (1.87 mb)