Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Carrier, Modèle INFINITY 2420

Fabricant : Carrier
Taille : 1.39 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. ! WARNING EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. This unit cannot be powered directly from blower motor leads. Do not wire directly to blower motor. Wiring to blower motor will damage power supply and void warranty. ! CAUTION A06414 Fig. 7 --- Flow Sensor Cable Installed A06413 Fig. 8 --- Power Cord Installed AIR FLOW SENSOR CABLE OR AIR FLOW SENSOR BYPASS PLUG MUST BE CONNECTED TOTHE POWER SUPPLY IN ORDER TO ACTIVATE THE AIR PURIFIER NOTICE A06670 Fig. 9 --- Airflow Sensor Bypass Plug Installed GAPAB 6 TO FAN COIL FIELD POWER CONNECTION FUSED POWER CONNECTOR LEADS FROM INSTALLATION COMPONENTS (IN BAG ATTACHED TO POWER CORD) AIR PURIFIER POWER CORD TO FAN COIL FIELD POWER CONNECTION TO L2 FIELD POWER SUPPLY TO L1 FIELD POWER SUPPLY 5 AMP IN-LINE FUSES GROUND: ATTACH TO FAN COIL GROUND (CHASSIS) CABLE CONNECTOR TO SECURE POWER CORD TO FAN COIL CABINET A06515 Fig. 10 --- Fan Coil Chassis Ground Air Flow Sensor 1) Slide flow sensor tabs into support bracket 2) Rotate flow sensor and clip into bracket A06412 Fig. 11 --- Flow Sensor Install GAPAB START- --UP AND OPERATION Step 1 — Checking Air Purifier Operation ! WARNING ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. a. Attach the Infinityt Air Purifier door to the cabinet. A magnet in the door (see Fig. 8) is used to activate a safety switch in the power supply when the door is installed. The power supply will not energize the air purifier unless the safety switch is activated. b. Turn the HVAC system power on and adjust the thermostat or Infinityt System Control to activate the system fan. c. Turn the Infinityt Air Purifier power switch to on position. d. The power indicator light above the Air Purifier power switch should illuminate (see Fig. 13). e. Check to ensure the light goes off when the Infinityt Air Purifier power switch is set to off, when the blower goes off, or when the HVAC system power is turned off. NOTE: Upon power- --up, the light will come on for approximately 5 seconds and if no flow is detected, it will go off. If no air purifier cartridge is detected, the flow sensor will detect this and turn off after approximately 7 seconds. Step 2 — Infinity Control a. When the Infinityt Air Purifier is used with an Infinity Control, the Infinity Control can be configured to remind the homeowner when it is time to change the Infinityt Air Purifier cartridge. This maintenance reminder can be based on either the TrueSenset dirty filter algorithm or time. The installer should use their discretion to select the most appropriate option based on the initial system static pressure. Step 3 — Maximizing Performance a. Maximum air purification performance is obtained when the furnace blower is set for continuous operation on the thermostat or Infinity Control. Door Switch Magnet A06379 Fig. 12 ---Door Switch Magnet Power Indicator A06380 Fig. 13 ---Power Indicator MAINTENANCE The Infinity t Air Purifier is designed to require minimal maintenance. Maintenance is limited to the replacement of the air purification cartridge and inspection/brush cleaning of the ionization array. Frequency of air purifier cartridge replacement and cleaning of the ionization array may vary depending on ductwork design and local environmental conditions. To replace the air purifier cartridge, complete the following steps: Step 1 — Turn the heating and cooling system power off. ! WARNING ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. Step 2 — Turn the Infinityt Air Purifier switch to the off position. Step 3 — Remove the Infinityt Air Purifier door. Step 4 — Slide out the old air purifier cartridge and discard. Step 5 — Install the new air purifier cartridge. NOTE: Make sure that the arrows on the air purifier cartridge point toward the fan coil. This should be in the same direction as airflow. Step 6 — Replace the Infinityt Air Purifier door. Step 7 — Turn the Infinityt Air Purifier switch to the on position. Step 8 — Turn heating and cooling system power on. GAPAB 7 8 At the time of air purifier cartridge replacement, if a powdery residue is noticed on the tips of the points in the ionization array, proceed to clean them by completing the following steps: Step 1 —Turn heating and cooling system power off. ELE...

Ce manuel est également adapté pour les modèles :
Air - INFINITY 1620 (1.39 mb)
Air - INFINITY 1620 (1.39 mb)
Air - INFINITY 2020 (1.39 mb)
Air - INFINITY 2020 (1.39 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories