Log:
Évaluations - 2, GPA: 4 ( )

Instructions Bryant, Modèle PERFECT AIR 2020

Fabricant : Bryant
Taille : 1.89 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This maintenance reminder can be based on either the TrueSenset dirty filter algorithm or time. The installer should use their discretion to select the most appropriate option based on the initial system static pressure. Step 3 — Maximizing Performance a. Maximum air purification performance is obtained when the furnace blower is set for continuous operation on the thermostat or Evolution Control. Door Switch Magnet A06369 Fig. 12 ---Door Switch Magnet Power Indicator A06370 Fig. 13 ---Power Indicator MAINTENANCE The Perfect Airt Air Purifier is designed to require minimal maintenance. Maintenance is limited to the replacement of the air purification cartridge and inspection/brush cleaning of the ionization array. Frequency of air purifier cartridge replacement and cleaning of the ionization array may vary depending on ductwork design and local environmental conditions. To replace the air purifier cartridge, complete the following steps: Step 1 — Turn the heating and cooling system power off. ! WARNING ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. Step 2 — Turn the Perfect Airt Air Purifier switch to the off position. Step 3 — Remove the Perfect Airt Air Purifier door. Step 4 — Slide out the old air purifier cartridge and discard. Step 5 — Install the new air purifier cartridge. NOTE: Make sure that the arrows on the air purifier cartridge point toward the fan coil. This should be in the same direction as airflow. Step 6 — Replace the Perfect Airt Air Purifier door. Step 7 — Turn the Perfect Airt Air Purifier switch to the on position. Step 8 — Turn heating and cooling system power on. GAPAB 7 8 At the time of air purifier cartridge replacement, if a powdery residue is noticed on the tips of the points in the ionization array, proceed to clean them by completing the following steps: Step 1 —Turn the heating and cooling system power off. ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch. ! WARNING Step 2 —Turn the Perfect Airt Air Purifier switch to the off position. Step 3 —Remove the Perfect Airt Air Purifier door. Step 4 —Unplug the power cord and flow sensor cable (if connected) from the enhancement module 9 ( See Fig. 7 and 8) Step 5 —Slide out the enhancement module assembly and safety screen. CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. ! WARNING Step 6 —Slide out the Safety Screen and set aside. NOTE: Best cleaning tools: 5 inch handle paint brush with 2 inch width (or greater) brush point (synthetic or natural bristle) (See Fig. 14) or vacuum cleaner with brush attachment. Step 7 —Gently stroke the ionization pins on the top plane of each bar with enough brush depth to hit front and back tips of the points in the ionization array. Use a gentle back and forth brushing motion to clean any small accumulations from the tips of the points. If desired, use vacuum cleaner with brush attachment to gently vacuum the frame and components of enhancement module. Step 8 —Reinstall the Safety Screen. Step 9 —Slide in enhancement module. Step 10 —Reconnect the power cord and flow sensor cable. Step 11 — Replace the Perfect Airt Air Purifier Door Step 12 —Turn the Perfect Airt Air Purifier switch to the on position. Step 13 —Turn heating and cooling system power on. 30° POINTS ARE SHARP! BE VERY CAREFUL DURING CLEANING. Tip of point with residue Tip of point after cleaning A06671 Fig. 14 --- Removal of Deposits from Ionization Pins GAPAB TROUBLESHOOTING CAUTION! SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage. The following instructions are for use by qualified personnel only. ! WARNING ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. The following procedures will expose electrical components. Disconnect power between checks and proceed carefully. The Perfect Airt Air Purifier is equipped with a power indicator light located on the door (see Fig. 13). This power indicator light will illuminate when the Perfect Airt Air Purifier door is installed, the power switch is in the on position, AND the fan coil blower is running and airflow is sensed. If the power indicator light is not illuminated, follow the troubleshooting steps below. Step 1 —Check that the Perfect Airt Air Purifier door is installed. NOTE: A magnet in the door (see Fig. 8) is used to activate a safety switch in the power supply when the door is installed. The power supply will not energize the air purifier un...

Ce manuel est également adapté pour les modèles :
Air - PERFECT AIR 1620 (1.89 mb)
Air - PERFECT AIR 2420 (1.89 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories