Log:
Évaluations - 2, GPA: 5 ( )

Instructions Panasonic, Modèle FP15HU2

Fabricant : Panasonic
Taille : 524.8 kb
Nom Fichier : FP15HU2.PDF
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


If you do, the filter life may be considerably diminished or the product may suffer damage. Care and maintenance A WARNING Before maintenance, be sure to unplug the power plug. Sudden unexpected operation of the product may cause injury or electric shock. Note Do not wipe with benzine or thinner. This may cause damage to the unit. 7 Care and maintenance Main unit (once a month or so Dampen a soft cloth with lukewarm water or diluted neutral kitchen detergent and wring it out. Wipe any stains off with the cloth and rub dry with another cloth. iHow to remove the air intake grille 0 Lay the main unit down on a table. (D While pressing the left and right holding tabs, lift up and out grille as illustrated. Holding tabs i How to reinstall the air intake grille © Align the top projections (4 places) with the depressions in the main unit. (D Press until the holding tabs lock. Depression Projection Air intake grille, filter unit (once a month or so) O © Remove the air intake grille. Clean the air intake grille. • Use a vacuum cleaner with dusting brush. • If stains are not completely removed, wash the air intake grille with water. © Wipe water off the grille with a soft cloth, and dry it completely. ©Remove dust on the surface of the filter. • Lightly vacuum with dusting brush do not apply too much pressure.If you do, the HEPA filter may be damaged. • Never wash the filter unit in water. © Reinstall the air intake grille. 8 Care and maintenance General timetable for filter changes • When it is obvious that odor or cigarette smoke is not quickly removed or the operating sound becomes louder than normal. Note The time of filter replacement may vary depending on condition of use. • New filters may be purchased through your local dealer or parts distributor using the following part numbers or call 1-800-332-5368 (PANASONIC SERVICE CENTER). Model No. F-P15HU2 F-P20HU1 HEPA filter Part No. F-Y15XS Part No. F-Y120XS Deodorizing filter Part No. F-Y55XS Part No. F-Y520XS Replacement of the filter The HEPA filter and the deodorizing filter can be separately replaced. ■ General timetable for filter replacement HEPA filter »When the filter check lamp’s red light is on (about 3 years after pressing the reset switch) •Even when the lamp is on, operation will not stop. Deodorizing filter »When the filter check lamp’s red light is on (about 1 year after pressing the reset switch) •Even when the lamp is on, operation will not stop. ■ How to replace the filter: Read the replacement instructions, on the replacement parts filter box. After replacing any of the filters, plug in the power cord and reset the corresponding reset switch, (refer to “before use”) HEPA Filter replacement ^ After replacement press the “HEPA” reset switch. Deodorizing filter replacement ^ After replacement press the “Deodorize” reset switch. (A beep sound should be heard when each reset switch is pressed). Filter Check/Reset HEPA Deodorize 0-0 O- \ier( Red) Filter frame Wring out a soft cloth dampened with lukewarm water or a diluted neutral detergent for kitchen use. Wipe any stains off with the cloth and rub dry with another cloth. Note • Do not rub the label too hard. (It will come off.) • Do not scrub the sealing material (black) on the filter frame. (The sealing material will be damaged, resulting in loss of performance.) 9 Care and maintenance Micro dust sensor If dust accumulates on the micro dust sensor, the AIR QUALITY MONITOR may not be displayed correctly. Maintain it frequently even during the first year of use, depending on the operating environment. o Remove the sensor cover on the right side of the main unit. • Press the hook to remove it. Note • Do not separate the black foam rubber attached to the inner surface of the sensor cover. If you do, sensitivity will be lost. © Remove the air intake grille and take out the cleaner.(Refer to Page 8.) Cleaning pad Cleaning pad storage © Clean the lenses (2 places) of the micro dust sensor with the cleaning pad. ©Insert the cleaning pad straight into the cleaning window. (D Remove any stains from the lenses (2 places) by rotating the cleaning pad in a side to side motion. Cleaning pad Lenses (2 places) Note • Do not use any detergent to maintain the lenses. • Wipe carefully. • If stains are not completely removed from the lenses with the cleaning pad, wipe them carefully with a commercial cotton swab. Install the sensor cover back on the main unit. • If you wash the stained cleaning pad with water, dry it thoroughly. Place the cleaning pad in the storage area, and reinstall the air intake grille. 10 Troubleshooting_ If a problem is encountered, investigate it by referring first to the table below. If you cannot correct it, unplug the power plug and consult an authorized service dealer. Symptom Check point Page The product does not operate. Is the power plug disconnected from the outlet? 5 No air comes ou...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories