Log:
Évaluations - 3, GPA: 4 ( )

Instructions Emerson, Modèle MEDIA AIR CLEANER ACM2000M-XXX

Fabricant : Emerson
Taille : 348.61 kb
Nom Fichier : 0037-7001.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


TABLE OF CONTENTS Rules for Safe Installation and Operation ......................2 How the Air Filter Works ................................................3 Construction of the Air Filter Compartment ...................3 Preinstallation ................................................................ 4 Installation ..................................................................... 6 Maintenance .................................................................. 6 Before installing the filter, make sure you have selected the proper size unit for your heating and cooling system requirements. See specifications on page 4. BASIC TOOLS REQUIRED • Tin Snip • Screwdriver • Ruler or Tape Measure • Drill 2 3 HOW THE AIR FILTER WORKS Dirty air fl ows through your return air ducts and enters the compartment where particles (hair, lint, etc.) are removed by the fi lter. See fi gure 1. Filtered air re-enters to the supply duct system of your building. DIRTY AIR IN 4" FILTER FILTERED AIR OUT CONSTRUCTION OF THE AIR FILTER COMPARTMENT Not only is your air fi lter compartment easy to install, it is also easy to maintain. Its basic components, and their functions, are as follows: (See Figure 2) Air Filter Cabinet – mounts to existing duct work and houses the fi lters 4” Filter – collects dust, dirt and other particles. SCREW AIR FILTER CABINET LATCH DOOR FILTER Figure 1 Figure 2 PREINSTALLATION LOCATING THE AIR FILTER Your air fi lter must be mounted in the return air duct of a central forced-air system, on the air entering side of your furnace. (See Figure 3 for example). Select a location that meets the following: 1. The face of the filter will be at a right angle to the air stream. 2. Allow 25” of clearance in front of the air filter compartment door to permit removal of filters. See figure 4 for complete compartment dimensions. AIR FLOW FURNACE OPENING TRANSITION SECTION (IF NEEDED) AIR CLEANER OPENING NOT TO EXCEED 20° DUCTWORK AIR CLEANERFURNACE 3. The air filter is not to be placed in the discharge of either the heating or cooling unit. 4. IMPORTANT: If atomizing spray type humidifier is used, it must be installed downstream from the air filter. If furnace opening cannot be enlarged to required size, a transition sheet metal section must be used. Transition must be planned for each job. Reduction should not be more than 4 inches per linear foot, approximately 20 angular degrees (Figure 3). AIR FLOW C B A Figure 4 LOCATING THE AIR FILTER AN AIR FILTER MUST BE MOUNTED IN THE RETURN AIR DUCT OF A CENTRAL FORCED-AIR SYSTEM, ON THE AIR ENTERING SIDE OF FURNACE. Figure 3 Model NO. ACM1000M-XXX ACM1400M-XXX ACM1600M-XXX ACM2000M-XXX A LENGTH 19-13/16 24-13/16 19-13/16 24-13/16 B HEIGHT C WIDTH CFM RATING 18-5/16 5-7/16 600 TO 1200 18-5/16 5-7/16 1000 TO 1600 22-5/16 5-7/16 1200 TO 1800 22-5/16 5-7/16 1800 TO 2200 4 TYPICAL MOUNTING POSITIONS AIR FLOW AIR FLOW Figure 5 BASEMENT FURNACE (LOWBOY) Filter is mounted horizontally in return plenum, just above furnac...

Ce manuel est également adapté pour les modèles :
Air - MEDIA AIR CLEANER ACM1400M-XXX (348.61 kb)
Air - MEDIA AIR CLEANER ACM1000M-XXX (348.61 kb)
Air - MEDIA AIR CLEANER ACM1600M-XXX (348.61 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories