Log:
Évaluations - 3, GPA: 4 ( )

Instructions Nordyne, Modèle AireCare 707831C

Fabricant : Nordyne
Taille : 307.6 kb
Nom Fichier : 4221bb2d-b511-4576-8d09-030292c931f2.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


iMPORTANT: Read all instructions carefully before starting the installation. Specifications or designs are subject to change or discontinuance without notice and without incurring obligations. These instructions are primarily intended to assist qualified individuals experienced in the proper installation of heating and/or air conditioning appliances. Some local codes require licensed installation/service personnel for this type of equipment. WARNING: improper installation may damage equipment, create a hazard, and will void thewarranty. DO NOT CONNECT TO 110 Volts AC -the unit is designed to operate on 24 VAC. /!X DANGER: Shut off electrical supply to the furnace at the household breaker box to prevent electrical shock and avoid injury. M1 AireCare TM Electronic Air Filter Installation Instructions Before starting this installation, make sure that all electrical power to the furnace has been disconnected. The M1 AireCare TM Electronic Air Filter kit con sists of two brackets, four screws, a filter grille, two protective edging strips, and the electronic air filter with power cable. To install the kit, the two brackets must be mounted onto the door of the M1 furnace as shown in Figure 1. Install the Brackets 1. install the protective sheet metal edging strips into the upper left louver of the M1 door (See Figure 1). 2. Locate the bottom bracket (See Figure 1) and remove the protective tape from the back. 3. Place the bracket into the bottom louver of the M1 door with the flange pointing towards the top of the door. Permanently mount the bracket to the door using two of the supplied screws. 4. Locate the top bracket (See Figure 1) and remove the protective tape from the back. 5. Place the bracket into the top louver of the M1 door with the flange pointing towards the bottom of the door. Permanently mount the bracket to the door using two of the supplied screws. Install the Filter 1. Connectthe electronicairfilterpowerwires (24 VAC) to the red and gray low voltage terminals (R and C). Run this wire through the left side of the top louver of the M1 door. Connect the power wire marked with white stripe or dash to C, the other to R. Place the door on the furnace and latch. 2. Place the electronic air filter into the brackets on the door by inserting it up into the top bracket then allowing it to drop into the bottom bracket. 3. Connect the electronic air filter power wire jack into the filter. Power the furnace. The AireCare TM Electronic Air Filter is active if the light on top of the electronic air filter is lit. 4. Place the filter grille over the top bracket. There are two tabs that attach the grille to the top bracket. The grille will now fit over the bottom bracket and is held there by a permanent magnetic. Protective Edging Strips AireCare Electronic Air Filter Upper Bracket Lower Bracket Grille Figure 1. M1 Bracket Installation E2 AireCare TM Electronic Air Filter installation Instructions (2-4 Ton A/C) Before starting this installation, make all electrical power to the furnace disconnected. sure that has been The E2 electronic air filter kit consists of one filter bracket, two screws, and the electronic air filter with power cable. Install the Brackets 1. Remove the grille from the top of the furnace. 2. As shown in Figure 2, place the filter bracket into the grille frame and attach using the two screws provided. Install the Electronic Air Filter 1. Connect the electronic air filter power wires (24 VAC) to the red and gray (or black) low voltage terminals (R and C) in the E2 furnace. Connect the power wire marked with a white stripe or dash to C, the other to R. 2. Place the filter into the filter bracket and connect the filter power cable by plugging it into the connector located at the top of the filter. 3. Turn on power to the furnace. The AireCare TM Electronic Air Filter is active if the light on top of the electronic air filter is lit. 4. Replace the grille. E2 AireCare TM Electronic Air Filter Installation Instructions (5 Ton A/C) Before starting this installation, make sure that all electrical power to the furnace has been disconnected. The 5 Ton E2 AireCare TM ElectronicAir Filter kit consists of a through the wall grille and frame kit and the electronic air filter with power cable. Install Frame 1. Cut a rough-in opening (20" wide by 30" high) in the door or wall enclosing the E2 furnace. 2. Mount the frame kit into the opening using screw or wall board anchors. Electronic Air Filter E2 Grille Connect the AireCare TM Electronic Air Filter 1. Connectthe electronicairfilterpowerwires (24 VAC) to the red and gray (or black) low voltage terminals (R and C). Run this wire from the E2 furnace to the electronic air filter and frame. Connect the power wire marked with a white stripe or dash to C, the other to R. 2. Place the electronic air filter into the frame and connect the filter power cable by plugging it into the connector located at the top of the electronic air filter. 3. Turn on power to the f...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories