Filter cleaning and exchange
Cleaning method of tray and humidifier filter
Classification Replacement cycle Cleaning cycle
Cleaning method
• When filling the water tank, fill up to 1/3 and rinse it 4-5 times to wash it out.
• Dissolve 10g of neutral detergent or citric acid in 1L of warm water for 1-2 hours, and then use the
Water tank

Daily
cleaning brush to clean the parts. After cleaning, make sure to rinse sufficiently. (After cleaning the
filter, close the front panel. If not closed completely, the product will not work.)
• Make sure to clean with a soft brush any white powder contents, around the filter or the case,
which may cause a smell or noise.
• Rinse the water tank by
• Wipe softly the
• When washing the
• After cleaning with
shaking 4-5 times.
humidifier filter with a
humidifier filter case,
neutral detergent or
Tray,

Daily
brush, by holding the
be careful as it can be
citric acid, rinse the
tray lid
case.
damaged.
filter with clean water.
More than
Humidifier
6-12
1 time
filter
months
weekly
• Citric acid: Can be purchased at pharmacy or on the Internet.
• Frequently wash the tray and humidifier filter. This will remove the scaling and you can use the product better sanitary condition.
• Do not disassemble the float of the tray. It can cause product failure.
2. Insert the float
If the product is disassembled by impact, assemble in the order show in the right picture.
1. Insert the
hook into the
• DO NOT take the humidifier filter case apart. This may result in deformation or damage in the filter or the case.
float under hole.
this hook.
• In cleaning, wipe the filter GENTLY with a brush, or the fiber can be degraded.
• If the part is not rinsed sufficiently it can carry the odor of the detergent or citric acid,
and can cause discoloration or deformation of the product.
Caution • White chunk can be attached on the humidifier filter or the filter can be discolored to red
or yellow during use. This is due to the impurity such as calcium included the tap water
3. Insert the hook on the other
and is a normal phenomenon.
side of the float to the hole.