|
Facilité d'utilisation
Young children should be supervised to ensure they do not play with the appliance. The appliance should only be connected up to the mains and taken into use by a qualified specialist. Dispose of packaging materials properly (see Installation instructions). Light bulbs must always be fitted when the extractor hood is in use. Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading. Never operate the extractor hood without a grease filter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. . Before using your new appliance, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance. . Please keep the operating and installation instructions in a safe place; this important documentation may also be of use to a possible subsequent owner. ! ! Do not flambe food directly under the extractor hood. Risk of grease filter catching fire due to flames. Restrictions apply to the use of the extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions). Gas hobs / gas cookers Always use gas hobs in a proper and safe manner. Important: The flames from the gas hob must always be covered by pots or pans. ! ! The intense heat generated by the gas flames could cause damage to the extractor hood. Operating procedure The most effective method of removing kitchen fumes is to: . switch on the extractor hood when you start cooking. . switch off the extractor hood a few minutes after you finishing cooking. . The fans in this appliance can be switched to the desired setting by hand (manual mode) or can be controlled fully automatically with the automatic function according to your requirements (automatic mode). Automatic mode / Manual mode Fan – off – Fan settings – lower – Fan – on – Fan settings – higher – Fan run-on / Intermittent ventilation Fan Display: Light on / off on / off . Fan settings / Intensive setting . Saturation – grease filter (#) . Saturation – activated carbon filter (a) Switching on manual mode: Switching over to automatic mode: Press the Lor + button. . To switch from manual mode to automatic mode at any time, press the U . The fan starts at Setting }. button. Switching on the fan settings/intensive setting: 1. To increase the fan settings or switch on the intensive setting c, press the + button. . The intensive setting operates at maximum power which should be used only briefly. If the intensive setting is not switched off manually, the fan automatically switches back to Setting }after 10 minutes. 2. To switch off the intensive setting c or switch back to fan settings ~ – } – |and switch off the extractor hood completely, press the – button. Operating procedure Switching on automatic mode: Press the Ubutton. . The fan runs at least at Setting |. Fan settings: . If required, the optimum fan setting is actuated automatically via a sensor. . The automatic function operates at Settings | – ~. Intensive setting: 1. To switch on the intensive setting c, press the + button. . Automatic mode has been switched off. . The intensive setting operates at maximum power which should be used only briefly. If the intensive setting is not switched off manually, the fan automatically switches back to the optimum fan setting after 10 minutes. 2. To switch off the intensive setting, press the – button. . Automatic mode has been switched on again. Switching over to manual mode: . To switch from automatic mode to manual mode at any time, press the U button. Intermittent ventilation . Used for ventilating the kitchen at hourly intervals at the lowest fan setting, round the clock. Switching on: . Before intermittent ventilation can be switched on, the appliance must be switched off. Press the button. . The fan runs for 5 minutes at Setting |, then switches off for 55 minutes. This process is repeated every hour. Switching off: Press the button. Operating procedure Switching off With fan run-on started from manual mode: Press the button. . The fan runs at the setting last selected. . The dot on the display flashes. . After 10 minutes the fan switches off and the displays go out. With fan run-on started from automatic mode: Press the button. . Fan run-on does not start until the automatic function has switched the fan back to Setting |. . The dot on the display flashes. . After 10 minutes the fan switches off and the displays go out. Without fan run-on: Press the Lbutton. Light . The light can be used at any time, even when the appliance has been switched off. Switching on/off: Press the a button. Special functions Adjusting the sensitivity of the sensor control: 1. Press and hold down the automatic button. 2. To display the current sensitivity, press the + or – button. 3. You can now change the sensitivity of the sensor control by pressing the + or – button. . Factory setting: @....
Ce manuel est également adapté pour les modèles :Hoods - DKE985S/08 (4.59 mb)
Hoods - DKE985S/09 (4.59 mb)
Hoods - DKE985S/10 (4.59 mb)