1.Carefully remove the bulb ring with a suitable tool. 2.Replace the defective bulb with a new one of the same type and equivalent power (see rating plate). NOTE:When inserting halogen bulbs, do not touch the glass tube. Therefore use a clean cloth when inserting the bulb. 3.Reinsert the bulb cover. 4.Restore the power supply by inserting the mains plug or switching on the fuse. Changing the filament bulbs 1.Lift the bulb cover slightly. 2.Push the bulb cover towards the middle of the appliance. 3.Replace the defective bulb with a new one of the same type and equivalent power (see rating plate). 4.Reinsert the bulb cover. 5.Restore the power supply by inserting the mains plug or switching on the fuse. NOTE:If the light does not function, check whether the bulbs have been inserted correctly. • Defective bulbs should be replaced immediately to avoid overloading the remaining bulbs. Installation instructions • Prior to installation, always follow the instructions and warnings in the chapter entitled ”Safety instructions”! Exhaust-air mode • The exhaust air is conveyed upwards via a ventilation shaft or directly through the outer wall to the exterior. NOTE: The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heating appliances. • Before conveying the exhaust air into a non-functioning smoke or exhaust gas flue, obtain the consent of the appropriate heating engineer. • Discharge exhaust air in accordance with the official and statutory regulations (e.g. regional building laws). • If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used. To ensure optimum performance, the extractor hood requires: – a short, straight exhaust air pipe and – the largest possible pipe diameter. • If pipe bends cannot be avoided, ensure the largest possible radii. NOTE: If long, rough exhaust air pipes, a lot of pipe bends or pipe diameters less than 150 mm are used, the air capacity will be less than optimum and there will be an increase in noise. • Use only pipes or hoses made of noncombustible material for installation of the exhaust air duct. • The manufacturer of the extractor hoods is not responsible for complaints which can be attributed to planning and design of the pipework. Connecting pipes • The diameter of the exhaust air pipes should not be less than 150 mm. • Round pipes: We recommend an inner diameter of 150 mm, however at least 120 mm. • Flat ductsmust have the same inner cross- section as round pipes. There should be no sharp bends. O150 mm approx. 177 cm2 O120 mm approx. 113 cm2 • If pipe diameters differ: Use sealing strips. Connection of 150 mm o exhaust air pipe(recommended size) • Attach exhaust air pipe directly to the air-pipe connector and seal appropriately. If using an aluminium pipe, smooth the connection area beforehand. Connection of 120 mm o exhaust air pipe • Attach reducing connector directly to the air- pipe connector. • Attach exhaust air pipe to the reducing connector. • Seal both joints appropriately. Installation instructions ELECTRICALCONNECTION • Before connecting the appliance to the power supply, always follow the instructions and warnings in the chapter entitled ”Safety instructions”! • The extractor hood may only be connected by a qualified electrician who is familiar with the regulations of the relevant electricity supply company. RISK OF INJURY If the power cord of the extractor hood is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualified person to prevent hazardous situations. • The extractor hood may be connected to a correctly installed earthed socket only. • Attach the earthed socket as directly as possible behind the flue duct. – The earthed socket should be connected via its own circuit. – If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be fitted as for a permanent connection. If a permanent connection is required • A disconnector must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as disconnectors. This includes LS switches, fuses and contactors. Electrical specifications The required connection data can be found on the rating plate inside the appliance when the grease filters have been removed. Length of the power cord: approx. 1.30 m. This extractor hood complies with the EC interference suppression regulations. Installation The extractor hood is designed to be mounted on the wall. • During installation, optional accessories may also require fitting. • Observe the minimum distance between hob and extractor hood (see ”Safety instructions”)! • Avoid damaging the sensitive surfaces! Preparing the wall RISK OF INJURY, DAMAGE TOPROPERTY Before drilling the holes for the designated installation location, check for concealed electrical cables and other lines. Th...

Ce manuel est également adapté pour les modèles :
Hoods - DWW126950/01 (3.87 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories