Fabricant : Bosch
Taille : 935.19 kb
Nom Fichier :
|
Facilité d'utilisation
Light bulbs must always be fitted when the extractor hood is in use. Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading. Never operate the extractor hood without a grease filter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. Carefully clean the extractor hood before switching on for the first time. Do not place any objects on the extractor hood. Never allow children to play with the appliance. Do not let adults or children operate the appliance unsupervised: – if they are mentally or physically unable to use the appliance safely and correctly, – if they don’t have the knowledge and experience to use the appliance safely and correctly. Operating procedure The most effective method of removing vapours produced during cooking is to: . Switch the ventilator ON as soon as you begin cooking. . Switch the ventilator OFF a few minutes after you have finished cooking. Light Display for fan setting Fan follow- on Fan OFF Reduce fan speed Fan ON and increase speed Intensive setting Acoustic signal: . When a button is pressed, this is verified by an acoustic signal. Switching the fan ON . Press the + button. Setting the required fan speed: . Press the + button. The fan speed is increased by one step. . Press the – button. The fan speed is reduced by one step. Switching the fan OFF: . Press the 0 button. The displayed { goes out shortly afterwards. Or: . Keep pressing the – button until the fan switches off. The displayed { goes out shortly afterwards. Intensive setting: Maximum power is obtained at the intensive setting. It is only required for short intervals. . Keep pressing the + button until a c appears in the display. . If the intensive setting is not cancelled by hand, the fan will automatically switch back to step } after 10 minutes. Fan follow-on: . Press the button. The fan continues to run at step | for 10 minutes, and at the same time a dot flashes in the display. After this period the fan switches off automatically. Lighting: . The light can be switched on at any time, even though the fan is switched off. Filters and maintenance Grease filters: Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from noncombustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: ~ When the grease filters becomes saturated, the display symbol # lights up and a signal sounds. The signal is switched off when the fan is switched off. The grease filters should be cleaned straight away. Cleaning the metal grease filters: . In normal operation (1 to 2 hours daily), the metal grease filter must be cleaned 1 x a month. . The filters can be cleaned in a dishwasher. It is however possible that they will become slightly discoloured. . The filter must be placed loosely, and NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. . When cleaning the filters by hand, soak them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and inserting the metal grease filters: Warning: The halogen bulbs must be switched off and cool. 1. Hold the sides of the edge extractor segment with both hands and pull it down. 2. Hold the side of the socket for the halogen lamps and pull it down. 3. Hold the grip at the rear of the grease filter. Pull it down and then off. 4. Clean the filters. 5. Insert the clean filters back into the hood. 6. Snap the socket for the halogen lamps back in. 7. Snap the edge extractor segment back in. 8. Clearing the # display. . Press the 0 button 2 x in succession. A signal sounds and the # display goes out. Cleaning and care Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine! . Clean the extractor hood with a hot soap solution or a mild window cleaner. . Do not scrape off dried-on dirt but wipe off with a damp cloth. . When cleaning the grease filters, remove grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. . Note: Do not use alcohol (spirit) on plastic surfaces, as dull marks may appear. Caution: Ensure that the kitchen is adequately ventilated. Avoid naked flam...
Ce manuel est également adapté pour les modèles :Hoods - D93K56N0GB/01 (935.2 kb)
Hoods - I93K56N0/01 (935.19 kb)
Hoods - I93K56N0GB/01 (935.2 kb)