Log:
Évaluations - , GPA: ( )

Instructions Bosch, Modèle D99L10N0/01

Fabricant : Bosch
Taille : 2.21 mb
Nom Fichier :

Langue d'enseignement: ruitenesfrdenl

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


• Use only pipes or hoses made of noncombustible material for installation of the exhaust air duct. • The manufacturer of the extractor hoods is not responsible for complaints which can be attributed to planning and design of the pipework. Connecting pipes • The diameter of the exhaust air pipes should not be less than 150 mm. Connection of 150 mm o exhaust air pipe (recommended size) • Attach exhaust air pipe directly to the air-pipe connector and seal appropriately. If using an aluminium pipe, smooth the connection area beforehand. ELECTRICAL CONNECTION • Before connecting the appliance to the power supply, always follow the instructions and warnings in the chapter entitled “Safety instructions”! • The extractor hood may only be connected by a qualiied electrician who is familiar with the regulations of the relevant electricity supply company. RISK OF INJURY If the power cord of the extractor hood is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualiied person to prevent hazardous situations. • The power cord must be stowed away securely following connection to the mains. • The extractor hood may be connected to a correctly installed earthed socket only. • Attach the earthed socket as directly as possible behind the lue duct. – The earthed socket should be connected via its own circuit. – If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be itted as for a permanent connection. If a permanent connection is required • A disconnector must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as disconnectors. This includes LS switches, fuses and contactors. Electrical speciications The required connection data can be found on the rating plate inside the appliance when the grease ilters have been removed. Length of the power cord: approx. 1.30 m This extractor hood complies with the EC interference suppression regulations. 15 Installation The extractor hood is designed to be mounted on the wall. During installation, optional accessories may also require itting. Observe the minimum distance between hob and extractor hood (see “Safety instructions”)! Avoid damaging the sensitive surfaces! Preparing the wall RISK OF INJURY, DAMAGE TO PROPERTY Before drilling the holes for the designated installation location, check for concealed electrical cables and other lines. The wall must be level and vertical. The enclosed screws and wall plugs are suitable for solid brickwork. Use the appropriate ixing materials for other wall structures (e.g. plaster board, porous concrete, poroton bricks). Ensure that the wall has adequate load bearing capacity. Ensure that the depth of the drilled holes corresponds with the length of the screws. Ensure that the wall plugs are secure. Max. weight in kg: 55 Design subject to modiication in line with technical development. Installation preparations 1. Using the enclosed template, mark positions for the screws and, to facilitate attachment, the contour of the attachment area. The lower edge of the template corresponds to the lower edge of the extractor hood. 2. Drill 2x 8 mm O holes for suspension of the extractor hood and press in wall plugs lush with the wall. 3. Screw on the brackets for the extractor hood: hand tight, max. 3 Nm Ensure that the washers and brackets are positioned correctly! Attachment and alignment 1. Mount the extractor hood, ensuring that the back is attached firmly to the brackets.. 2. Align the extractor hood horizontally by turning the brackets. If required, the extractor hood can be moved to the right or left .. 983 10 209 2x Locking screws and locking caps 1. Mark the holes for the safety screws. Detach the extractor hood, drill holes for the safety screws and press in wall plugs lush with the wall. 2. Attach the extractor hood and screw in the safety screws tightly. 3. Press the safety caps with the arrow upwards onto the brackets until they click into position .. RISK OF INJURY Check that all locking screws and locking caps have been attached securely! 4. Connect the pipes (see “Connecting pipes”). 5. Connect to the power supply (see “Electrical connection”). Removing the safety caps Remove the locking caps from the brackets using a suitable tool, e.g. a latblade screwdriver. 2x C Installation Installing the lue ducts 4. Push lue duct upwards until it clicks into position. RISK OF INJURY 5. Insert metal-mesh grease ilter. The insides of the lue ducts may have sharp edges. We recommend wearing protective gloves during installation. 1. Remove the protective ilm from both lue ducts. 2. Insert lue into the guide rails and slide down. 112 3. Insert 2 securing elements and screw tight. 2x Tabel de matieres Notice d’utilisation Informations generales ........................................................................................ 17 Conseils pour le respect de l’environnem...

Ce manuel est également adapté pour les modèles :
Hoods - D99L10N0/02 (2.21 mb)
Hoods - D99L10N0GB/01 (2.21 mb)
Hoods - D99L10N0GB/02 (2.21 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories