Log:
Évaluations - 0, GPA: 0 ( )

Instructions Bosch, Modèle D99L11N0/01

Fabricant : Bosch
Taille : 2.51 mb
Nom Fichier :
Langue d'enseignement: ruitenesfrdenl
Aller à la télécharger



Facilité d'utilisation


The appliance surfaces and controls are scratch-sensitive. Therefore observe the following cleaning instructions: – Avoid cleaning the extractor hood with dry cloths, abrasive sponges, scouring agents, cleaning agents containing sand, soda, acid, chlorine or any other aggressive substances. – Clean the appliance surfaces and controls with a soft, damp cloth, washing-up liquid or a mild window cleaner only. – Do not scrape of dried dirt, but moisten with a damp cloth. – Clean carefully in the area of the controls to avoid liquid from getting into the electronics. NOTE: Clean the stainless steel surfaces in the direction of the ground surface only! Do not use stainless steel cleaner for the control buttons! Looking after the appliance Suitable cleaning agents and care products for your appliance can be purchased via the Hotline or from the Online Shop (see cover page). Metal-mesh grease ilters The inserted metal-mesh grease ilters absorb the grease particles from the kitchen fumes. The ilter mats consist of ire-proof metal. RISK OF FIRE As the ilters become more saturated with greasy residue, the lammability increases. The function of the extractor hood may also be impaired. The risk of ire is prevented by cleaning the metal-mesh grease ilters in good time. When cleaning the grease ilters, also remove grease deposits from the accessible parts of the housing with a damp cloth. Cleaning the metal-mesh grease ilters ... Under normal operation (daily 1 to 2 hours), the metal-mesh grease ilters must be cleaned 1x month. ... in the dishwasher The metal-mesh grease ilters can be cleaned in the dishwasher. Slight discolouration may occur but this will not afect the function of the grease ilters. The ilters must be placed loosely in the dishwasher. They must not be wedged in. NOTE: Do not clean heavily saturated metalmesh grease ilters together with utensils. ... by hand When cleaning by hand, soak the grease ilters in a hot detergent solution, brush of the dirt, rinse thoroughly and leave to dry. Do not use any aggressive, acidic or alkaline cleaning agents. If dirt is particularly stubborn, we recommend using a special grease solvent spray. This can be ordered via the Online Shop. Removing and installing the grease ilters Before removing and installing the grease ilters, always follow the instructions and warnings in the chapter entitled “Safety instructions”! Removing and installing the metal-mesh grease ilters 1. Open the lock and fold down the grease ilters. In doing so, hold the underside of the grease ilters with your other hand. 2. Clean the grease ilters. 3. Reinsert the cleaned grease ilters. Changing the activated carbon ilter Under normal operation (daily 1 to 2 hours) the activated carbon ilters must be replaced approximately 2x year. The activated carbon ilter is available from specialist outlets, customer service or the Online Shop (see Optional accessories). Use original ilters only. Activated carbon ilters do not contain any pollutants. They can be disposed of in the household refuse. 1. Remove metal-mesh grease ilter. 2. Unlock lue duct on both sides and slide downwards. 3. Remove both activated-carbon ilters forwards and replace. 4. Push lue duct upwards until it clicks into position. 13 Electrical connection Before connecting the appliance to the power supply, always follow the instructions and warnings in the chapter entitled ”Safety instructions”! The extractor hood may only be connected by a qualiied electrician who is familiar with the regulations of the relevant electricity supply company. RISK OF INJURY If the power cord of the extractor hood is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualiied person to prevent hazardous situations. The power cord must be stowed away securely following connection to the mains. The extractor hood may be connected to a correctly installed earthed socket only. Attach the earthed socket as directly as possible behind the lue duct. – The earthed socket should be connected via its own circuit. – If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be itted as for a permanent connection. If a permanent connection is required A disconnector must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as disconnectors. This includes LS switches, fuses and contactors. Electrical speciications The required connection data can be found on the rating plate inside the appliance when the grease ilters have been removed. Length of the power cord: approx. 1.30 m This extractor hood complies with the EC interference suppression regulations. Installation Prior to installation, always follow the instructions and warnings in the chapter entitled “Safety instructions”. The extractor hood is designed to be mounted on the wall. During installation, optional accessories may also requi...

Ce manuel est également adapté pour les modèles :
Hoods - D99L11N0/02 (2.51 mb)
Hoods - D99L11N0GB/01 (2.51 mb)
Hoods - D99L11N0GB/02 (2.51 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories