|
Facilité d'utilisation
Contact the after-sales service. ¦ Incorrect repairs are dangerous. Repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service. ¦ Penetrating moisture may cause an electric shock. Do not use any high- pressure cleaners or steam cleaners. Causes of damage Caution! Risk of damage due to corrosion. Always switch on the appliance while cooking to avoid condensation. Condensate can produce corrosion damage. Always replace faulty bulbs to prevent the remaining bulbs from overloading. Risk of damage due to ingress of humidity into the electronic circuitry. Never clean operator controls with a wet cloth. Surface damage due to incorrect cleaning. Clean stainless steel surfaces in the direction of the grain only. Do not use any stainless steel cleaners for operator controls. Surface damage due to strong or abrasive cleaning agents. Never use strong and abrasive cleaning agents. Risk of damage from returning condensate. Install the exhaust duct in such a way that it falls away from the appliance slightly (1° slope). Environmental protection Unpack the appliance and dispose of the packaging in an Environmental protection environmentally-responsible manner. This appliance is labelled in accordance with the European Directive 2012/19/EU concerning used electrical and electronic appliances (WEEE – waste electrical and electronic equipment). The guideline determines the framework for the return and recycling of used appliances as applicable. Operating modes This appliance can be used in exhaust-air mode or circulating- air mode. Exhaust air mode The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system. Note: The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heating appliances. ¦ Before conveying the exhaust air into a non-functioning smoke or exhaust gas flue, obtain the consent of the heating engineer responsible. ¦ If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used. Circulating-air mode The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen. Note: To bind odours in circulating-air mode, you must install an activated carbon filter. The different options for operating the appliance in circulating-air mode can be found in the brochure. Alternatively, ask your dealer. The required accessories are available from specialist outlets, from customer service or from the Online Shop. The accessory numbers can be found at the end of the instructions for use. Getting to know the appliance Control panel Explanation 1 Flue 2 Lighting 3 Control panel 4 Metal mesh grease filter Explanation 1 Fan On/Off 2 Fan on, turn fan up 3 Display panel 4 Turn the fan down 5 Fan run-on time 6 Switch on lighting Operating the appliance Note: Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking. This is the most effective way of removing the kitchen fumes. Setting the fan Note: Always adjust the fan strength to meet current conditions. If there is a large build-up of steam or fumes, select a high fan setting. Switching on ¦ Press the #button. The fan starts at setting 2. ¦ Press the + or -button to change the fan strength. Switching off Press the #button. Intensive setting You can use the intensive setting if there is a large build-up of odours and fumes/vapours. There are two different intensive settings available:.‚ -duration: 5 minutes .. -duration: 10 minutes ¦ Press the + button while the appliance is at ventilation setting „. The intensive setting .‚ is activated. ¦ Press the + button again to activate the intensive setting ... Once the preset time has elapsed, the electronics automatically switch the appliance back down to ventilation setting .. If you wish to end the intensive setting before the preset time expires, press the -button until the required setting is reached. Fan run-on time Press the $button. %and «appear in the display. The run-on time is six minutes. Once this time has elapsed, ventilation switches off automatically. If the lighting is switched on, it remains on. Setting the run-on time During the fan run-on time, press the + or -buttons. You can set the following run-on times: Display ¬: three minutes Display «: six minutes Display .: nine minutes Interval ventilation With "interval ventilation", the ventilation switches on automatically for five minutes each hour. ¦ To switch on interval ventilation, press the $button twice. This operating mode is indicated by the $symbol in the display. ¦ To switch off interval ventilation, press the # button. Lighting The lighting can be switched on and off ind...
Ce manuel est également adapté pour les modèles :Hoods - D99L20N0/02 (2.18 mb)
Hoods - D99L20N0GB/01 (2.18 mb)
Hoods - D99L20N0GB/02 (2.18 mb)