Fabricant : Bosch
Taille : 2.61 mb
Nom Fichier :
|
Facilité d'utilisation
O 150 mm approx. 177 cm2 O 120 mm approx. 113 cm2 ¦ Flat ducts should have no sharp deflections. ¦ Use sealing strip for deviating pipe diameters. Checking the wall ¦ The wall must be level, vertical and adequately load-bearing. ¦ The depth of the boreholes must be the same length as the screws. The wall plugs must have a secure grip. ¦ The enclosed screws and wall plugs are suitable for solid brickwork. Suitable fasteners must be used for other structures (e.g. plasterboard, porous concrete, poroton bricks). ¦ The max. weight of the extractor hood is 40 kg. Preparing the installation 1.Mark a vertical centre line on the wall from the ceiling to the lower edge of the extractor hood. 2.Mark positions for the screws and the contour of the attachment area. 3.Drill five 8 mm O holes to a depth of 80 mm for the attachments and press in the wall plugs flush with the wall. Installation 1.Screw on the fixing bracket for the flue duct. . 9 2. Screw on brackets for the extractor hood hand-tight, max. 3 Nm. © 3. Screw in threaded pin, leaving it protruding out of the wall by 5–9 mm. . Attaching and aligning the appliance 1. Initially remove the protective foil from the back of the appliance and, following installation, remove foil completely. 2.When attaching the appliance, ensure that it engages firmly with the brackets. « 3. Align the appliance horizontally by turning the brackets. If required, the appliance can be moved to the right or left. ¬ Securing the appliance 1. Press the safety caps with the arrow upwards onto the brackets until they engage. ® 2. Screw on knurled nut and washer firmly. . Removing safety caps If the safety caps have to be removed, use a flat screwdriver. .................. .................. ! " Connecting the pipes Note: If using an aluminium pipe, smooth the connection area beforehand. Exhaust-air pipe O 150 mm (recommended size) Attach exhaust-air pipe directly to the air-pipe connector and seal. Exhaust-air pipe O 120 mm 1. Attach reducing connector directly to the air-pipe connector. 2. Attach exhaust air pipe to the reducing connector. 3. Seal both joints appropriately. Electrical connection a=Risk of electric shock! from damaged connection cable. Do not kink or pinch connection cable during installation. The required connection data can be found on the rating plate inside the appliance; to do this, remove the metal-mesh grease filter. Length of the connection cable: approx. 1.30 m This appliance complies with the EC interference suppression regulations. This appliance may be connected to a correctly installed earthed socket only. Attach the earthed socket preferably inside the flue duct. ¦ The earthed socket should be connected via its own circuit. ¦ If the earthed socket is no longer accessible following installation of the appliance, a disconnector must be fitted as for a permanent connection. If a permanent connection is required, the installation must feature an all-pole disconnector (circuit breakers, fuse...
Ce manuel est également adapté pour les modèles :Hoods - LC64GA520B/02 (2.61 mb)
Hoods - LC64GA520B/03 (2.61 mb)
Hoods - LC66BB530/01 (2.61 mb)
Hoods - LC66BB530/02 (2.61 mb)