Log:
Évaluations - 0, GPA: 0 ( )

Instructions Bosch, Modèle VL430107/01

Fabricant : Bosch
Taille : 252.74 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :
Hoods - VL430107/01 (254.08 kb)de
Hoods - VL430107/01 (269.66 kb)es
Hoods - VL430107/01 (290.13 kb)ru

Facilité d'utilisation


Consult the chimney sweep responsible for your district whenever you wish to pass the exhaust air into a chimney that is not in operation. Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the ventilator is installed. The applicable regulations of the power supply companies and the regional construction regulations must be observed when installing the hob ventilator. Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means. Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 125 mm. Pay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short as possible – the pipes are not laid at an acute angle, but as bends and that they are inserted into the shaft at an inclined upward angle and – there are no cross-sectional constrictions in the upward direction (this reduces the volume flow). To prevent the ingress of water, e.g. condensate or rain water from an uncovered exhaust air shaft, our condensate separator RV 050-150 must be installed in the proximity of the hob ventilator. The condensate separator must still be accessible after installation. Technical modifications reserved. Installing the appliance 820 min. 35 min. 50 490 128 0450 80 93 510 162 140 50 140 O 125 135 85 Blow-out opening: downward or at the side If two Vario appliances are used, the hob ventilator must be installed between the appliances. If 4-plate hobs are used, it is recommended to place two ventilators to the left and right of the hob. Owing to the high air output, an adequate supply of air is required. If you have installed a gas appliance between the hob extractors VL 430/431, the gas hob has to be fitted with two air baffles LS 330 on the side of the hob while cooking. The air baffles not only improve the airflow of the extractor next to a gas appliance, but also prevent a flame which has been set to a low level from being extinguished. If you have installed the hob extractor only on one side of the gas appliance, it is sufficient to fit one air baffle LS 330 on the side facing the extractor. Note: do not install this appliance next to a VG 411 gas cooker. The hob ventilator is installed at the side of the Vario appliance without any gap between the appliances. • As standard, the blow-out direction is downward. Proceed as follows to establish a blow-out opening at the side: – Undo all 5 screws on the connection piece and detach the connection piece. – Undo the screws of the side cover. – Screw the connection piece onto the side opening and the cover onto the bottom opening. • Cut out the recess for one or several Vario appliances in your worktop. Proceed as indicated on the installation sketch. • Peel the protective film off the sealing tape. Stick the sealing tape to the front and rear of the cut out, so that half of the tape overlaps on the inside. • On the side of the ventilator, press the seal into the groove provided. • T urn the clamping screws to the side. Insert the appliance with the control panel on the front into the cut-out and align it. Note: do not stick the appliance onto the worktop with silicone. • T urn the clamping screws under the countertop and tighten them evenly. Do not tighten the clamping screws too tightly, as a uniform sealing gap should be left all round. • Connect the appliance to the fan module by means of a flexible aluminium pipe with a diameter of 125 mm. • Connect the appliance to the fan module by means of the 4-pole plug. We recommend the use of our telescopic wall box TM 180-043 to route exhaust air through the outside wall. Installing the edge trim AL 400-000 The edge trim has to be fitted to the side of the hob ventilator, if this ventilator is installed together with other Vario appliances and forms the left or right edge of this combination. The edge trim does not change the total width of the cut-out, however, the width of the edge trim has to be added to the total width of the appliance combination. Simply press the edge trim under that side of the ventilator, that forms the edge of the combination. The hooks on the side of the edge trim will latch into the openings provided on the hob ventilator. Connectors VL 431 connecting cable to GB connecting cable to VL 430 Connectors VL 431 connecting cable to GB connecting cable to VL 430 Electrical connection Pay attention to the rating plate data. Observe the connecting scheme when connecting the hob ventilator and the fan module. 9000029649 en 12.04 EB GAGGENAU HAUSGERATE GMBH CARL-WER...

Ce manuel est également adapté pour les modèles :
Hoods - VL431107/01 (252.74 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories