Facilité d'utilisation


Clicking Motor, switches or solenoid valves are switching on/off. Rumbling Ready ice cubes from the ice maker are falling into the ice cube container. Preventing noises The appliance is not level Please align the appliance with a spirit level. Use the height-adjustable feet or place packing underneath them. The appliance is not free-standing Please move the appliance away from adjacent units or appliances. Containers or storage areas wobble or stick Please check the removable parts and re-insert them correctly if required. Bottles or receptacles are touching each other Move the bottles or receptacles slightly away from each other. en Eliminating minor faults yourself Before you call customer service: Please check whether you can eliminate the fault yourself based on the following information. Customer service will charge you for advice – even if the appliance is still under guarantee! Appliance Fault Possible cause Remedial action Appliance has no refrigeration capacity. The light does not work. The display does not illuminate. Appliance has been switched off. Power failure. The fuse has been switched off. The mains plug has not been inserted properly. Press the On/Off button. Check whether the power is on. Check the fuse. Check whether the mains plug is secure. The refrigeration unit is switching on more frequently and for longer. Appliance opened frequently. The ventilation openings have been covered. Do not open the appliance unnecessarily. Remove obstacles. Large quantities of fresh food are placed in the freezer. Activate “super” cooling and/or “super” freezing. The light (LED) does not work. The LED lamp is defective. Call customer service. Light switch is jammed. Check whether it can be moved. Display indicates “E..”. Electronics have detected a fault. Call customer service. Display indicates “LOWPOWER”. The mains voltage falls below the permitted limiting value. When the mains voltage reaches the stipulated value again, the warning message goes out. If the warning message lasts for longer, inform the energy supply company. Ice maker Fault Possible cause Remedial action The ice maker doesn’t work. Ice maker is not connected to the mains supply. Call customer service. Ice maker does not contain any fresh water. Ensure that the water is properly connected. The freezer compartment temperature is too warm. Check freezer compartment temperature and, if required, set slightly colder. The ice maker does not make enough ice or the ice is deformed. The appliance or ice maker has only just been switched on. A lot of ice has been taken. Approx. 24 hours is needed until ice production starts. Approx. 24 hours is needed until the ice cube container is filled again. Low water pressure. Connect the appliance to the stipulated water pressure only (see chapter Connecting appliance, section Water connection). The water filter is bunged up or used. Change the water filter. en Fault Possible cause Remedial action The ice maker does not make any ice. The ice maker is switched off. The appliance is not supplied with water. Switch the ice maker on at the control panel. Contact the installer or the water supply company. Water supply has kinks. Turn off the water supply at the shut-off tap. Smoothen out the kinks, exchange where necessary. Low water pressure. Connect the appliance to the stipulated water pressure only (see chapter Connecting appliance, section Water connection). Temperature in the freezer space is too warm. Check freezer compartment temperature and, if required, set slightly colder. Ice cube container is not properly inserted. Check the position, re-insert where necessary. Incorrect shut-off tap installed. Incorrect taps can cause low water pressure and damage to the appliance. Ice maker sensor is blocked. Pull out and empty ice cube container. Remove ice from the sensor. Ice forms in the inflow hose to the ice maker. Low water pressure. Connect the appliance to the stipulated water pressure only (see chapter Connecting appliance, section Water connection). Shut off tap incorrectly opened. Open shut off tap fully. Temperature in the freezer space is too warm. Set temperature slightly colder in the freezer compartment. Water runs from the appliance. The water connection hose is not properly sealed. Replace the hose with a manufacturer’s original part. Incorrect shut-off tap installed. Incorrect taps can cause low water pressure and damage to the appliance. The water pressure is less than usual. Low water pressure. Connect the appliance to the stipulated water pressure only (see chapter Connecting appliance, section Water connection). Shut off tap incorrectly opened. Open shut off tap fully and check for leaks. Check the minimum through flow. Incorrect shut-off tap installed. Incorrect taps can cause low water pressure and damage to the appliance. Water supply has kinks. Turn off the water supply at the shut-off tap. Smoothen out the kinks, exchange where necessary. The water filter is bunged up or used. Chang...

Ce manuel est également adapté pour les modèles :
Réfrigérateurs - FI24DP31AU/05 (6.68 mb)
Réfrigérateurs - FI24DP31AU/08 (6.68 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories