Log:
Évaluations - 3, GPA: 4.7 ( )

Instructions Energizer, Modèle IEC-LR43

Fabricant : Energizer
Taille : 73.75 kb
Nom Fichier : 884910f2-df2c-dd74-2904-5f22e4036398.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Permissible deflection from a flat 0.13 (0.005) Minimum Ref. (applies to top edge of gasket or edge of crimp, whicever is higher) Designed for electronic applications which may require high rate pulses Typical Discharge Characteristics 21°C (70°F) Load: 15K ohms - Continuous Typical Drain @ 1.25V: 0.083 mA 1. 1. 0. 300 600 900 Service, Hours 1200 1500 Chemical System: Designation: Nominal Voltage: Typical Capacity: Typical Weight: Typical Volume: Specifications Manganese Dioxide (MnO2) IEC-LR43 1.5 Volts 123 mAh (to 0.9 volts) Rated at 15K ohms / 21°C (70°F) 1.4 grams (0.05 ounces) 0.40 cubic centimeters (0.05 cubic inch) Cross Section Anode Cap Cathode Depth of Discharge Test Percent of rated Capacity at 21°C (70°F) Typical closed circuit voltage during discharge on a load of 100 ohms for 0.1 to 2.0 seconds % Rated Capacity 0% 1.52V 40% 1.19V 80% 1.07V Bulge Data This battery will bulge as it is discharged but will not exceed the maximum height shown on the battery drawing. Schedule: Continuous Typical Drains: at 1.25 V (milliamperes) 0.083 Load (ohms) 15,000 Cutoff 0.9V (hours) 1,482 Important Notice This data sheet contains typical information specific to products manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty. 0 Form No. EBC - 4401F Page 1 of 1...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories