Log:
Évaluations - 0, GPA: 0 ( )

Instructions Philips, Modèle HX6985/10

Fabricant : Philips
Taille : 2.04 mb
Nom Fichier :
Langue d'enseignement: itenfrdenl
Aller à la télécharger



Facilité d'utilisation


If you want to shor ten the mains cord, you can store excess cord in the cord wrap feature built into the charger base. 1 To separate the charger cover from the charger base, press the two grey snap bars on the charger base and pull the white charger cover upwards. 2 Wrap excess power cord around the grey charger base as shown in the picture. Be sure to wrap the cord on the inside of the two snap levers. 3 4 When you have stored the excess cord, guide the mains cord through the small groove in the rear of the grey charger base. To reattach the charger cover, press it down over the charger baseuntil it snaps into place. Tip: For extra convenience during travel, you can remove the travel charger and use it without the charger cover and charger base. Cord wrap on sanitiser with integrated charger (specific types only) -If your type includes the sanitiser, you can store excess cord in the cord wrap feature built into the bottom of the sanitiser. 10 EnglisH Sanitising (specific types only) -With the UV sanitiser you can clean your brush head after ever y use. Discontinue use of the sanitiser if the UV light bulb remains on when the door is open or if the blue window is broken or missing from the sanitiser. UV light can be harmful to the human eye and skin.This appliance should be kept out of reach of children at all times. Unplug the sanitiser and call Consumer Care if the sanitiser gives off smoke or a burning smell while it is operating. 1 After brushing, rinse the brush head and shake off excess water. Do not place the travel cap on the brush head during sanitisation. 2 Place your finger in the door recess on top of the sanitiser and pull open the door. 3 Place the brush head on one of the 2 pegs in the sanitiser. -Make sure the bristles of the brush head directly face the light bulb. Note: Only clean Sonicare ProResults brush heads in the sanitiser. 4 5 Make sure the sanitiser is plugged into the wall socket. Close the door and press the green power on/off button once to select the UV clean cycle. Note:You can only switch on the sanitiser if the door is properly closed. Note:The sanitiser stops if you open the door during the sanitising cycle. Note:The sanitiser cycle runs for 10 minutes and then automatically switches off. The sanitiser is in operation when the blue light glows through the , window. When the sanitising cycle is complete, the sanitiser automatically , switches off. cleaning Do not clean the brush head, handle, travel charger, charger cover and the UV sanitiser in the dishwasher. EnglisH 11 Toothbrush handle 1 Remove the brush head and rinse the metal shaft area with warm water. Do not push on the rubber seal on the metal shaft with sharp objects, as this may cause damage. 2 Use a damp cloth to wipe the entire surface of the handle. Brush head 1 2 Rinse the brush head and bristles after each use. Remove the brush head from the handle and rinse the brush head connection at least once a week with warm water. charger 1 2 Unplug the charger. Use a damp cloth to wipe the surface of the charger. Sanitiser (specific types only) Do not clean the sanitiser when the UV light bulb is hot. For optimal effectiveness, it is recommended to clean the sanitiser weekly. 1 2 3 4 Unplug the sanitiser. Pull the drip tray straight out. Rinse the drip tray and wipe it clean with a damp cloth. Clean all reflector surfaces with a damp cloth. Remove the protective screen in front of the UV light bulb. To remove the screen, grasp the edges next to the snaps, gently squeeze and pull it out. 5 Remove the UV light bulb. To remove the light bulb, grasp it and pull it out of the metal clasp. 6 7 Clean the protective screen and the UV light bulb with a damp cloth. Reinsert the UV light bulb. To reinser t the light bulb, align the bottom of the light bulb with the metal clasp and push the bulb into the clasp. 8 Reinsert the protective screen. 12 EnglisH To reinser t the screen, align the pegs on the screen with the slots on the reflective surface near the UV light bulb. Push the screen straight into the slots on the sanitiser. storage -If you are not going to use the appliance for an extended period of time, remove the mains plug from the wall socket. Then clean the appliance and store it in a cool and dr y place away from direct sunlight. You can use the cord wrap feature to store the mains cord neatly. replacement Brush head -Replace Sonicare brush heads ever y 3 months to achieve optimal results. -Use only compatible Sonicare replacement brush heads. uV light bulb -You can order replacement UV light bulbs from the Consumer Care Centre in your countr y or an authorised Philips ser vice centre. Environment -The built-in rechargeable batter y contains substances that may pollute the environment. Always remove the batter y before you discard and hand in the appliance at an official collection point. Dispose of the batter y at an official collection point for batteries. If you have trouble removing the batter y, you can also ta...

Ce manuel est également adapté pour les modèles :
Brosses à dents - HX6992/03 (2.04 mb)
Brosses à dents - HX6995/10 (2.04 mb)
Brosses à dents - HX6952 (2.04 mb)
Brosses à dents - HX6952/71 (2.04 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories