Log:
Évaluations - 0, GPA: 0 ( )

Instructions Philips, Modèle HX6921/02

Fabricant : Philips
Taille : 1.12 mb
Nom Fichier :
Langue d'enseignement: enesfr
Photos et spécifications   Philips  HX6921/02
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


Note:The sanitizer cycle runs for 10 minutes and then automatically shuts off. The sanitizer is in operation when the blue light glows through the , window. When the sanitizing cycle is complete, the sanitizer automatically , shuts off. ENGLISH 11 Cleaning Do not clean the brush head, handle, travel charger, charger cover and the UV sanitizer in the dishwasher. Toothbrush handle 1 Remove the brush head and rinse the metal shaft area with warm water. Do not push on the rubber seal on the metal shaft with sharp objects, as this may cause damage. 2 Use a damp cloth to wipe the entire surface of the handle. Brush head 1 Rinse the brush head and bristles after each use. 2 Remove the brush head from the handle and rinse the brush head connection at least once a week with warm water. Charger 1 Unplug the charger. 2 Use a damp cloth to wipe the surface of the charger. Brush head UV Sanitizer (select models) Do not clean the sanitizer when the UV light bulb is hot. For optimal effectiveness, it is recommended to clean your sanitizer weekly. 1 Unplug the sanitizer. 2 Pull the drip tray straight out. Rinse the drip tray and wipe it clean with a damp cloth. 3 Clean all reflector surfaces with a damp cloth. 4 Remove the protective screen in front of the UV light bulb. To remove the screen, grasp the edges next to the snaps, gently squeeze and pull out the protective screen. 5 Remove the UV light bulb. To remove the light bulb, grasp it and pull it out of the metal clasp. 12 ENGLISH Storage Replacement Disposal 6 Clean the protective screen and the UV light bulb with a damp cloth. 7 Reinsert the UV light bulb. To reinser t the light bulb, align the bottom of the light bulb with the metal clasp and push the bulb into the clasp. 8 Reinsert the protective screen. To reinser t the screen, align the pegs on the screen with the slots on the reflective surface near the UV light bulb. Push the screen straight into the slots on the sanitizer. -If you are not going to use the product for an extended period of time, unplug it from the electrical outlet, clean it and store it in a cool and dr y place away from direct sunlight.You can use the cord wrap to store the power cord in an organized manner. Brush head -Replace Sonicare brush heads ever y 3 months to achieve optimal results. -Use only compatible Sonicare replacement brush heads. UV light bulb -Replacement UV bulbs are available through your Sonicare Consumer Care Center in Nor th America by calling 1-800-682-7664. Outside Nor th America, contact your local Philips Consumer Care Center. -The rechargeable batter y inside your Sonicare cannot be replaced, but is easy to remove for recycling. At the end of product life and prior to disposal, please remove the rechargeable batter y from the handle by following the instructions below. -Do not throw away the appliance or the UV light bulb (bulb contains mercury) with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preser ve the environment. -If you have any recycling questions, contact your local waste management offi ce. ENGLISH 13 Removing the rechargeable battery Please note that this process is not reversible. To remove the rechargeable battery, you need a fl at-head (standard) screwdriver. Obser ve basic safety precautions when you follow the procedure outlined below. Be sure to protect your eyes, hands, fi ngers, and the surface on which you work. To deplete the rechargeable battery of any charge, remove the handle from the charger, turn on the Sonicare and let it run until it stops. Repeat this step until you can no longer switch on the Sonicare. Insert a screwdriver into the slot located at the bottom of the handle and turn counterclockwise to release the bottom cap. Hold the handle upside down and push down on the shaft to release the internal components of the handle. Insert the screwdriver under the circuit board, next to the battery connections, and twist to break the connections. Remove the circuit board and pry the battery from the plastic carrier. The rechargeable battery can now be recycled and the rest of the product discarded appropriately. Guarantee and service 1 2 3 4 Philips guarantees its products for two years after the date of purchase. Defects due to faulty materials and workmanship will be repaired or replaced at Philips expense provided that convincing proof of purchase in the qualifying period is provided. Contact our Consumer Care Center at 1-800-682-7664 (Nor th America), outside Nor th America contact your local Philips Consumer Care Center. Internet information: (Nor th America) or com (outside Nor th America). 14 ENGLISH WARRANTY EXCLUSIONS What is not covered under warranty: -Brush heads -Damage caused by misuse, abuse, neglect, alterations or unauthorized repair. -Normal wear and tear, including chips, scratches, abrasions, discoloration or fading. -UV light bulb IMPLIED WARRANT...

Ce manuel est également adapté pour les modèles :
Brosses à dents - HX6972/10 (1.12 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories