|
Facilité d'utilisation
power > 70% into 1W load at max. power > 70% into 1W load at max. power Externally Bridgeable yes yes yes Remote Bass Function yes (HP-RB1 supplied) yes (HP-RB1 supplied) yes (HP-RB1 supplied) Distortion at Rated Power < 1.0% THD+N < 1.0% THD+N < 1.0% THD+N Frequency Response 20Hz to 250Hz ±2.5dB 20Hz to 250Hz ±2.5dB 20Hz to 250Hz ±2.5dB Linear Bandwidth 10Hz to 500Hz ±3dB 10Hz to 500Hz ±3dB 10Hz to 500Hz ±3dB Damping Factor > 200 > 200 > 200 Input Sensitivity 150mV to 5V rms 150mV to 5V rms 150mV to 5V rms Supply Voltage Range 9 to 16V 9 to 16V 9 to 16V Protection thermal, DC offset, reverse polarity, short protection, under-voltage, over-voltage thermal, DC offset, reverse polarity, short protection, under-voltage, over-voltage thermal, DC offset, reverse polarity, short protection, under-voltage, over-voltage Terminal Wire Gauge Power 0/1 AWG, Remote 12 AWG, Ground 0/1AWG, Speaker 12 AWG Power 0/1 AWG, Remote 12 AWG, Ground 0/1AWG, Speaker 12 AWG Power 0/1 AWG, Remote 12 AWG, Ground 0/1AWG, Speaker 12 AWG Input Impedance 20kW 20kW 20kW Fuse Type (2) 30 Amp (3) 40 Amp In-line 250 Amp Dimensions 13"x10.5"x2.3" 13"x10.5"x2.3" 13"x10.5"x2.3" Weight 8 lbs. 8 lbs. 8 lbs. Crossover Section High Pass Crossover Continuously variable (20-150Hz) Continuously variable (20-150Hz) Continuously variable (20-150Hz) Low Pass Crossover Continuously variable (30-250Hz) Continuously variable (30-250Hz) Continuously variable (30-250Hz) Infrasonic Filter Selectable On/Off 24dB/Octave -6dB at 20Hz Selectable On/Off 24dB/Octave -6dB at 20Hz Selectable On/Off 24dB/Octave -6dB at 20Hz Intelli-Q 0–10dB boost 0–10dB boost 0–10dB boost 1. Continuous 4W load 20Hz to 200Hz, < 1% THD, with input voltage at 14.4VDC. 2. Continuous 2W load 20Hz to 200Hz, < 1% THD, with input voltage at 14.4VDC. © 2005 Directed Electronics, all rights reserved AMPLIFIER SETTINGS Signal Input and Output Configurations The input section of the amplifier consists of a phase switch that sets the output configuration, infrasonic switch, gain controls, high pass and low pass crossovers controls, Intelli-Q control, and RCA inputs. The input section makes it easy to adapt this amplifier to most system configurations. Input Gain These Orion amplifiers have level adjustments to allow for easy integration with any source unit. The input sensitivity can be adjusted from 150mV to 5V. Refer to Testing the System and Adjusting the Sound of the System sections of this guide for detailed instructions on setting the gain. Phase Switches . 0° -leaves output unaffected. The output signal is in phase with the input signal. . 180° -inverts the output. The channel is 180° output of phase. This configuration is useful for inverting the phase of subwoofers to improve staging in a vehicle. This is also used when bridging two amplifiers into one speaker. Line Output Configurations (System Expansion) NOTE: When expanding your system by adding additional Orion amplifiers in the signal chain use only the same model(s) as the first amplier in the chain. The line outputs on Orion amplifiers offer easy, unlimited system expansion. Routing signal from a source unit, pre-amplifier, or equalizer is a matter of connecting RCAs to the RCA Inputs of the first Orion amplifier and then the RCA line outputs to the next Orion amplifier’s RCA line inputs in the signal chain. Then the Master/Slave switch on each of the amplifers is set as follows: The first amplifier in the signal chain will have its Master/Slave switch set to the MASTER position. In effect this first amplifier will set the gain for the remainder of the amplifiers in the signal chain. The remaining amplifiers following in the signal chain will have their Master/Slave switch set to the SLAVE position. This allows the signal to be input directly, bypassing the subsequent amplifiers gain control. The audio level is set and supplied by the output of the master amplifier at its gain setting. Internal Crossover Configurations The crossover section of the Orion HCCA-D1200, HCCA-D2400, and HCCA-D5000 amplifiers is continuously variable and extremely flexible. In addition to the variable built-in low-pass filters, the high-pass crossover incorporates the INTELLi Q feature. This circuit is designed to optimize the performance of Orion subwoofers in all types of enclosures. When using Orion loudspeakers, minor deviations from the recommended frequency ranges can provide superior results depending on your speaker locations and your vehicle acoustics. Setting crossover frequencies higher than recommended will not cause damage and may provide superior sonic results depending on your system's performance goals. Refer to your loudspeaker owner's manual for assistance in choosing the proper crossover frequencies for your system. © 2005 Directed Electronics, all rights reserved WARNING! DO NOT set crossover frequencies lower than the speakers recommended operating range. This can cause driver failure that is not covered by the man ufacturer's warranty...
Ce manuel est également adapté pour les modèles :Avtousiliteli - HCCA-D1200 (637.39 kb)
Avtousiliteli - HCCA-D2400 (637.39 kb)
Avtousiliteli - HCCA-D5000 (637.39 kb)