(During operation, it is always ON) • QUIET can't be selected in FAN MODE. • Sleep-timer can't be used. And you can't use both wired remote control unit and wireless simultaneously. (Only one kind can be selected) En-3 Fig. 1 Indoor Unit 1 Operating Control Panel (Fig. 2) 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start. The forced cooling operation is used at the time of installation. Only for authorized service personnel’s use. When the forced cooling operation starts by any chance, press the START/STOP button to stop the operation. 3 Indicator (Fig. 3) 4 Remote Control Signal Receiver 5 OPERATION Indicator Lamp (red) 6 TIMER Indicator Lamp (green) If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 17 Auto Restart). 7 AIR CLEAN Indicator Lamp (green) 8 COIL DRY Indicator Lamp (orange) 9 Intake Grille (Fig. 4) 0 Air Filter A Air Flow Direction Louver B Right-Left Louver (behind Air Flow Direction Louver) C Drain Hose D Electrical Air Cleaning Filter E Power Supply Cord F Power Supply Plug Fig. 5 Outdoor Unit G Intake Port H Outlet Port I Pipe Unit J Drain port (bottom) NAME OF PARTS Refer to the folded out page on the cover. Fig. 6 Remote Control Unit K Signal Transmitter L MASTER CONTROL button M FAN CONTROL button N START/STOP button O AIR CLEAN button P COIL DRY button Q SET button R SET TEMP. button ( / ) S SLEEP button T SWING button U TIMER MODE button V TIMER SET ( / )buttons W TEST RUN button This button is used when installing the conditioner, and should not be used under normal conditions, as it will cause the air conditioner’s thermostat function to operate incorrectly. If this button is pressed during normal operation, the unit will switch to test operation mode, and the Indoor Unit’s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously. To stop the test operation mode, press the START/STOP button to stop the air conditioner. X CLOCK ADJUST button Y RESET button Z Remote Control Unit Display (Fig. 7) [ Temperature SET Display \ Transmit Display ] Operating Mode Display ` Fan Speed Display a AIR CLEAN Display b SWING Display c COIL DRY Display d Timer Mode Display e SLEEP Display f Clock Display En-4 PREPARATION CAUTION! Take care to prevent infants from accidentally swallowing batteries. When not using the Remote Control Unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit. If leaking battery fluid comes in contact with your skin, eyes, or mouth, immediately wash with copious amounts of water, and consult your physician. Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority. Do not attempt to recharge dry batteries. Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the Remote Control Unit’s operating range becomes appreciably reduced, replace the batteries and press the RESET button with the tip of a ballpoint pen or other small object. Turn on the Power 1 Connect the Power Supply Plug (Fig. 1 F) to an electrical outlet; in the case of a direct line connection, turn on the circuit breaker. Load Batteries (AAA/R03/LR03 . 2) 1 Press and slide the battery compartment lid on the reverse side to open it. Slide in the direction of the arrow while pressing the mark. 2 Insert batteries. Be sure to align the battery polarities ( ) correctly. 3 Close the battery compartment lid. Set the Current time 1 Press the CLOCK ADJUST button (Fig. 6 X). Use the tip of a ball-point pen or other small object to press the button. 2 Use the TIMER SET ( / ) buttons (Fig. 6 V) to adjust the clock to the current time. button: Press to advance the time. button: Press to reverse the time. (Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.) 3 Press the CLOCK ADJUST button (Fig. 6 X) again. This completes the time setting and starts the clock. To Use the Remote Control Unit The Remote Control Unit must be pointed at signal receiver (Fig. 3 4) to operate correctly. Operating Range: About 23 ft. When a signal is properly received by the air conditioner, a beeping sound will be heard. If no beep is heard, press the Remote Control Unit button again. Remote Control Unit Holder 3 To remove the Remote Control Unit (when use at hand). 1 Mount the Holder. 2 Set the Remote Control Unit. Screws Insert Press in Slide up Pull out En-5 To Select Mode Operation 1 Press the START/STOP button (Fig.6 N). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light. The air conditioner will start operating. 2 Press the MASTER CONTROL button (Fig.6 L) to select the desired mode. Each time t...

Ce manuel est également adapté pour les modèles :
Climatiseurs - AOU15RLQ (554.77 kb)
Climatiseurs - AOU18RLQ (554.77 kb)
Climatiseurs - ASU15RLQ (554.77 kb)
Climatiseurs - ASU18RLQ (554.77 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories