Log:
Évaluations - 4, GPA: 4.3 ( )

Instructions Sony, Modèle ICD-B5

Fabricant : Sony
Taille : 591.53 kb
Nom Fichier : 3242997121.pdf
Langue d'enseignement: en
Photos et spécifications   Sony  ICD-B5
Aller à la télécharger



Par ce dispositif a également d'autres instructions :
Dictation - ICD-B5 (605.56 kb)es
Dictation - ICD-B5 (584.9 kb)de
Dictation - ICD-B5 (597.92 kb)en

Facilité d'utilisation


The message will be divided in two messages; however, the messages will be recorded without a break. 1 Tip You can add an index during recording pause. To add an index during playback While playing back a message, press INDEX at the point you want to divide. The message is divided in two and the new message number flashes three times. An index mark is added and the following index numbers will increase by one. 1 Tip You can add an index after you have paused playback with XPAUSE. To play the message you marked with an index Press –. or >+ to display the message number as the divided messages each have message numbers. To play the divided messages continuously Select “ON” for “CONT” as described in “Playing Back All Messages in a Folder Continuously.” Notes • If 99 messages have been recorded in a folder, you cannot add an index. In that case, reduce the number of messages to 98 or less by erasing unnecessary messages or by moving some of the messages to another folder before adding an index. • If you add an index to a message with an alarm setting, the alarm setting remains only with the former message divided. Combining Messages by Erasing the Index You can combine two messages into one by erasing the index. In stop mode, follow the steps below: 1 Press – . or >+ to display the number of the second of the two messages you want to combine. 2 While pressing ERASE, press INDEX for more than 1 second. “ID ERASE” will flash for 10 seconds. 3 Press ERASE while the display is flashing. The two messages are combined into one and the messages will be renumbered as in the illustration above. To cancel erasing Press STOP before step 3. Notes on adding/erasing index When recording with an IC recorder, the following symptoms may occur because of the limitation of the system, however, they are not malfunction. • If you add/erase indexes frequently, the unit may become unable to add/erase indexes. • You cannot add an index in the first or the last 1 second. • After combining messages by erasing an index, the latter message’s alarm setting will be erased. Message 4 Before adding an index After adding an index The message numbers increase. The first item on the agenda is... We will now proceed to the next subject. An index is added. 3While the display is flashing, press ERASE. Message 3 An index is added. Recording continues Moving Messages to a Different Folder — Move Function You can move the recorded messages to another folder. Example: Moving Message 3 in Folder A to Folder B 1 Play back the message you want to move. 2 While playing back the message, press FOLDER to flash the indication of the folder to which you want to move the message (B in this case). The first and last 5 seconds of the message will be played back 10 times, while the folder indication and “MOVE” flash. 3 Press NxPLAY/STOP. The message is moved in the destination folder. Messages are sorted in order of the recorded date and time. To cancel moving the message(s) Press STOP before step 3. Note The move function does not duplicate a message in another folder. When you move a message to another folder, the one in the previous folder will be deleted. Playing Back a Message at a Desired Time with an Alarm You can sound an alarm and start playback of a selected message at a desired time. 1 Use FOLDER and – ./ >+ to select the folder and the message you want to play back. 2 Enter the alarm setting mode. 1 Press MENU. The unit enters the menu mode and “ALARM OFF” will be displayed. (If “ALARM ON” is displayed, the alarm has been set. If you do not wish to change the setting, press MENU and exit the menu mode.) Note “ALARM OFF (or ON)” will not appear and the alarm cannot be set if the clock has not been set or no message has been recorded in the selected folder. 2 Press NxPLAY/STOP. “OFF” starts to flash. 3 Press – . or >+ to flash “ON”. 4 Press NxPLAY/STOP. “DATE” will flash in the display window. 3 Set the alarm date. To play back on a desired date (the message will be played back at the same time on the same date every year until you erase the message) 1 Press NxPLAY/STOP while “DATE” is flashing. The month digits will flash. 2 Press – . or >+ to select the month digits and press NxPLAY/STOP. The day digits will flash. 3 Press – . or >+ to select the day digits. To play back once a week Press – . or >+ to select the day of the week. To play back at the same time every day Press – . or >+ to select “DAILY”. Message 1 Message 2 Message 3 Message 4 Message 1 Message 2 Message 3 The message numbers decrease. An index is erased. During playback of Message 3 After adding a recording Message 4 at Conference room A Message 4 Added recording 1 During playback, press zREC/ STOP for more than 1 second. The REC indicator appears and “PLUS” flashes three times on the display window. The OPR indicator will turn red. The new recording will be added at the end of the current message. 2 Press zREC/STOP or STOP to stop the recording. Recording with an External Microphone o...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories